Dell Networking PowerSwitch OS9: How To Configure Port Monitoring
概要: This article explains how to set up and verify Port Monitoring (Mirroring) on Dell Networking OS9 Switches.
この記事は次に適用されます:
この記事は次には適用されません:
この記事は、特定の製品に関連付けられていません。
すべての製品パージョンがこの記事に記載されているわけではありません。
手順
Important things to Know
- Port Monitoring is supported on both physical and logical interfaces like virtual local area network (VLAN) and port-channel.
- The monitored (the source) and monitoring ports (the destination) must be on the same switch.
- In general, a monitoring port should have no IP address and no shutdown as the only configuration. A monitoring port may also not be a member of a VLAN.
- There may only be one destination port in a monitoring session.
- A Port monitoring session can have multiple source statements.
- One Destination Port can be used in multiple sessions.
Configure Port Monitor Session
|
Command |
Purpose |
|
|
Enter configuration mode. |
|
|
Enter the destination port to be used for monitor session. Confirm that it has no configuration. |
Force10(conf-if-te-0/2)# no switchport |
Remove any Layer 2 that may be configured. |
|
|
Remove any IP address that may be configured. |
|
|
Enable the port. |
|
|
Leave the destination port interface. |
|
|
Set up and identify the session number. Range 0 - 65535. |
|
|
Set the source (the port you want to monitor). Set the destination (the port where you send the monitored packets). Set the direction (Both/Rx/Tx). |
Verify Port Monitor Session
Force10#show monitor session 0
SessID Source Destination Dir Mode Source IP Best IP
------ ------ ----------- --- ---- --------- --------
0 Te 0/1 Te 0/2 both Port N/A N/A