PowerProtect Data Domain: iDRAC Flea Drain Procedure | BMC Reset

요약: This article provides instructions for performing a flea drain (legacy BMC reset) on Dell PowerEdge-based PowerProtect Data Domain appliances. This procedure can help resolve various system issues without requiring physical intervention. ...

이 문서는 다음에 적용됩니다. 이 문서는 다음에 적용되지 않습니다. 이 문서는 특정 제품과 관련이 없습니다. 모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.

지침

Symptoms

  • iDRAC becomes unresponsive or behaves erratically
  • System health indicators show inconsistent or stale data
  • Hardware management functions fail to operate correctly
  • Remote access or monitoring issues persist despite reboots

Applies To:

  • PowerProtect Data Domain systems
    • Based on the PowerEdge platform (such as, DD3300, DD9900, DD9910)
  • All Software versions

iDRAC Remote Flea Drain Procedure:

Note: These steps simulate having AC power removed from the system; DO NOT send an FE to site for a Flea Drain.
  1. Log in to the iDRAC console.

  2. Go to Configuration.

  3. Click BIOS Settings.
    iDRAC UI BIOS settings menu

  4. Scroll and select Miscellaneous Settings.
    Miscellaneous Settings

  5. Select Power Cycle Request.

  6. Change the value to Full Power Cycle.

  7. Click  Apply and Reboot to proceed with the remote flea drain.

  8. Monitor the job cycle using the virtual console.

    NOTE: iDRAC connection is lost during the remote flea drain.

    This can also be done using the following RACADM CLI commands:

    racadm set BIOS.MiscSettings.PowerCycleRequest FullPowerCycle
    racadm jobqueue create BIOS.Setup.1-1
    reboot

Alternative: Manual Flea Drain Procedure:

Note: Dell Support: DO NOT send a Field Engineer to site to perform these actions - customer must make their own arrangements to do these steps.
  1. Power the Data Domain down gracefully.
  2. Disconnect the server from all power and network cables.
  3. Hold down the power button continuously for at least 10 s.
  4. Insert power and network cables back to the system.
  5. Wait 2 minutes before powering on the server to give the iDRAC time to initialize.
  6. Power the system on.

해당 제품

DD3300 Appliance, DD6900 Appliance, DD9400 Appliance, DD9900 Appliance

제품

Data Domain, Data Domain
문서 속성
문서 번호: 000194110
문서 유형: How To
마지막 수정 시간: 30 10월 2025
버전:  10
다른 Dell 사용자에게 질문에 대한 답변 찾기
지원 서비스
디바이스에 지원 서비스가 적용되는지 확인하십시오.