Dell Unity: Código de error de motivo del rescate del procesador de almacenamiento: 0x1b01
Samenvatting: Un procesador de almacenamiento (SP) de Unity falla y entra en modo de servicio con el código de error 0xb01, 6913 o 1:1678040.
Dit artikel is van toepassing op
Dit artikel is niet van toepassing op
Dit artikel is niet gebonden aan een specifiek product.
Niet alle productversies worden in dit artikel vermeld.
Symptomen
Uno o ambos procesadores de almacenamiento pueden estar en modo de servicio con el siguiente motivo de rescate:
======== Now executing basic state ========
* System Serial Number is: APM00172106812
* System Friendly Host Name is: (none)
* Current Software version: Unable to determine full software version.
* Unisphere IP address(es): 10.90.24.250 fe80::260:1600:47e0:2a26
* FIPS mode: Disabled
* Boot Mode: Rescue Mode
* Post Faults: 0x0000
* Backend Faults: 0x0000
* Boot Faults: 0x1b00
* Rescue Reason: 0x1b01
* Rescue reason for code 0x1b01 - There is a problem with the system software on this Storage Processor. To attempt to correct this problem, first run Data Collection, and then try the following in order: Check all cables, reboot each SP, and reimage each Storage Processor (SP). If this does not resolve the issue, contact your service provider.
Durante este problema, también se pueden generar los siguientes códigos y mensajes de error adicionales:
ERROR" "1:1678040Storage Processor SP B has faulted and is in Service Mode with reason code 6913Storage Processor SP A has faulted and is in Service Mode with reason code 6913SERVICE_ERR_0x1b01
Oorzaak
La variable sep Por lo general, este problema se debe a que se encuentre en el servicio SAFE. Como evidencia de esto, revise las siguientes ubicaciones de registros:
/EMC/C4Core/log/start_c4.log:
Wed Sep 27 19:00:53 2017: start_c4.pl: *****************************************************
Wed Sep 27 19:00:53 2017: start_c4.pl: * Error Detected SP Degraded Mode after sep started.
Wed Sep 27 19:00:53 2017: start_c4.pl: * Incrementing SOFTWARE boot counter
Wed Sep 27 19:00:53 2017: start_c4.pl: * Driver rrchc code: 0x1b01
Wed Sep 27 19:00:53 2017: start_c4.pl: *****************************************************
/var/log/boot.out:
2017-09-29 18:36:31.598 ===== bringup_backend =====
2017-09-29 18:36:32.105 Loading mirror driver
2017-09-29 18:36:37.787 read degraded mode bit from nvram and check if sep is degraded
2017-09-29 18:36:37.996 MCR database degraded mode: 00000001
2017-09-29 18:36:38.332 1
2017-09-29 18:36:39.064 =================================================================
2017-09-29 18:36:39.068 === *** Going into service mode because of a fault *** ===
2017-09-29 18:36:39.072 =================================================================
2017-09-29 18:36:39.082 === When escalating to platform services, please make sure to ===
2017-09-29 18:36:39.086 === include the messages ABOVE this notice. You can ignore ===
2017-09-29 18:36:39.090 === any errors below. ===
2017-09-29 18:36:39.094 =================================================================Oplossing
Comuníquese con el soporte técnico de Dell o con su representante de servicio autorizado y mencione este ID de artículo de la base de conocimientos de Dell.
Getroffen producten
Dell EMC Unity, Dell EMC Unity Family |Dell EMC Unity All Flash, Dell EMC Unity HybridArtikeleigenschappen
Artikelnummer: 000032808
Artikeltype: Solution
Laatst aangepast: 11 nov. 2025
Versie: 4
Vind antwoorden op uw vragen via andere Dell gebruikers
Support Services
Controleer of uw apparaat wordt gedekt door Support Services.