Dell Unity: Kod błędu Przyczyna ratowania procesora pamięci masowej: 0x1b01

Samenvatting: Procesor pamięci masowej (SP) Unity ulega awarii i przechodzi w tryb serwisowy z kodem błędu 0xb01, 6913 lub 1:1678040.

Dit artikel is van toepassing op Dit artikel is niet van toepassing op Dit artikel is niet gebonden aan een specifiek product. Niet alle productversies worden in dit artikel vermeld.

Symptomen

Jeden lub oba procesory pamięci masowej mogą być uruchomione w trybie serwisowym z następującej przyczyny ratunkowej:

======== Now executing basic state ========
* System Serial Number is: APM00172106812
* System Friendly Host Name is: (none)
* Current Software version: Unable to determine full software version.
* Unisphere IP address(es): 10.90.24.250 fe80::260:1600:47e0:2a26
* FIPS mode: Disabled
* Boot Mode: Rescue Mode
* Post Faults:  0x0000
* Backend Faults:       0x0000
* Boot Faults:  0x1b00
* Rescue Reason:        0x1b01
* Rescue reason for code 0x1b01 - There is a problem with the system software on this Storage Processor. To attempt to correct this problem, first run Data Collection, and then try the following in order: Check all cables, reboot each SP, and reimage each Storage Processor (SP). If this does not resolve the issue, contact your service provider.

 

W przypadku tego problemu mogą również zostać wygenerowane następujące dodatkowe kody błędów i komunikaty:

  • ERROR" "1:1678040
  • Storage Processor SP B has faulted and is in Service Mode with reason code 6913
  • Storage Processor SP A has faulted and is in Service Mode with reason code 6913
  • SERVICE_ERR_0x1b01

Oorzaak

Polecenie sep Ten problem jest zazwyczaj spowodowany modułem w usłudze Safe. Aby uzyskać na to dowód, zapoznaj się z następującymi lokalizacjami dzienników:

 

/EMC/C4Core/log/start_c4.log:

Wed Sep 27 19:00:53 2017: start_c4.pl:  *****************************************************
Wed Sep 27 19:00:53 2017: start_c4.pl:  * Error Detected SP Degraded Mode after sep started.
Wed Sep 27 19:00:53 2017: start_c4.pl:  * Incrementing SOFTWARE boot counter
Wed Sep 27 19:00:53 2017: start_c4.pl:  * Driver rrchc code: 0x1b01
Wed Sep 27 19:00:53 2017: start_c4.pl:  *****************************************************

 

/var/log/boot.out:

2017-09-29 18:36:31.598 ===== bringup_backend =====
2017-09-29 18:36:32.105 Loading mirror driver
2017-09-29 18:36:37.787 read degraded mode bit from nvram and check if sep is degraded
2017-09-29 18:36:37.996 MCR database degraded mode:  00000001
2017-09-29 18:36:38.332 1
2017-09-29 18:36:39.064 =================================================================
2017-09-29 18:36:39.068 ===   ***  Going into service mode because of a fault  ***    ===
2017-09-29 18:36:39.072 =================================================================
2017-09-29 18:36:39.082 === When escalating to platform services, please make sure to ===
2017-09-29 18:36:39.086 === include the messages ABOVE this notice. You can ignore    ===
2017-09-29 18:36:39.090 === any errors below.                                         ===
2017-09-29 18:36:39.094 =================================================================

Oplossing

Prosimy skontaktować się z działem pomocy technicznej firmy Dell lub z autoryzowanym przedstawicielem serwisu i podać ten identyfikator artykułu z bazy wiedzy firmy Dell.

Getroffen producten

Dell EMC Unity, Dell EMC Unity Family |Dell EMC Unity All Flash, Dell EMC Unity Hybrid