PowerStore: Pre-Upgrade Health Check (PUHC) detects incorrect drive Database signature

Resumo: The PowerStore pre-upgrade health check (PUHC) may fail the incorrect drive database validation (off_release_drivedb_check) with the following error: Incorrect Drive Database is detected. ...

Este artigo aplica-se a Este artigo não se aplica a Este artigo não está vinculado a nenhum produto específico. Nem todas as versões do produto estão identificadas neste artigo.

Sintomas

The PowerStore pre-upgrade health check (PUHC) may fail the incorrect drive database (off_release_drivedb_check) validation, with the following error: Incorrect Drive Database is detected. Please contact your service provider. (off_release_drivedb_check).

The health check is an off-release PUHC check that is contained in the Health Check thin package.

The following snapshot is displayed in the PowerStore Manager when the issue is detected: image.png

Causa

This issue only affects: 
    • Upgrade to PowerStoreOS version: 3.6.1.0-2261541
    • NVME drives SAMSUNG TLA 005648566.

When this issue exists, a data unavailable condition may occur if all of the following conditions apply:
    a) The appliance has impacted drives. 
    b) NDU to 3.6.1.0-2261541 is performed.
    c) NVME expansion enclosure or base enclosure (DPE) with the impacted drives was previously reinitialized in field.

This issue is a result of the removal of the DriveDB file after the NVME expansion enclosure or DPE is reinitialized.

Resolução

Contact Dell Technical Support to resolve this issue. Reference this KB Article for expedited handling.

Produtos afetados

PowerStore
Propriedades do artigo
Número do artigo: 000224852
Tipo de artigo: Solution
Último modificado: 14 jun. 2025
Versão:  3
Encontre as respostas de outros usuários da Dell para suas perguntas.
Serviços de suporte
Verifique se o dispositivo está coberto pelos serviços de suporte.