NetWorker: Restore performed through NetWorker User reports the error "Please Specify AM or PM" When attempting to change browse time.

Resumo: A recovery is being performed from the NetWorker User software, when attempting to change browse time an error appears stating: "PM@#$%# is not a valid time designation in 12-hour format. Please Specify AM or PM" ...

Este artigo aplica-se a Este artigo não se aplica a Este artigo não está vinculado a nenhum produto específico. Nem todas as versões do produto estão identificadas neste artigo.

Sintomas

  • A restore is being performed using the NetWorker User program.
  • The following error when changing browse time using 12-hour format.
Not a valid time designation in 12 hour format 

Causa

Code defect. Observed using NetWorker 19.7.0.1 client on Windows Server 2016. NetWorker 19.7 is End of Support Life (EOSL).

 

Resolução

This issue was not observed when using NetWorker 19.11.0 (or later) client on Windows Server 2022 or 2025. This issue is unlikely on current NetWorker releases and operating systems. If encountered, use the workaround below.

Workaround: 

  1. From NetWorker User, select View->Change Browse Time
  2. Specify a time (in a 12-hour format) that you would like to set the browse period to. Insert a space before AM or PM.
There is a space preceding the AM PM in the time settings
  1. Click Ok
  2. The browse time should now reflect the time that is specified.

Produtos afetados

NetWorker Family, NetWorker

Produtos

NetWorker Series
Propriedades do artigo
Número do artigo: 000201625
Tipo de artigo: Solution
Último modificado: 30 dez. 2025
Versão:  3
Encontre as respostas de outros usuários da Dell para suas perguntas.
Serviços de suporte
Verifique se o dispositivo está coberto pelos serviços de suporte.