Data Domain 云数据移动故障处理

Resumo: 调查数据移动故障或问题的基本故障处理步骤。

Este artigo aplica-se a Este artigo não se aplica a Este artigo não está vinculado a nenhum produto específico. Nem todas as versões do produto estão identificadas neste artigo.

Instruções

  • 检查系统警报
 sysadmin@dd4500# alerts show current
 
Id             Post Time                               Severity         Class             Object                Message
------        -----------------------                  --------            ----------        -------------           ------------------------------------------------------------------
p0-469   Thu Aug 10 11:44:41 2023   CRITICAL      Filesystem   FilesysType=8   EVT-SPACE-00004: Space usage in cloud unit "ECS" has exceeded 100% threshold.
p0-470   Thu Aug 11 06:13:18 2023   CRITICAL      Filesystem   FilesysType=2   EVT-SPACE-00004: Space usage in Data Collection has exceeded 90% threshold.
mo-307  Sun Aug 13 04:17:20 2023   CRITICAL      Filesysm       Tier=ECS            EVT-FMIG-00001: Data Movement has encountered an error
------        -----------------------                  --------            ----------        -------------           ------------------------------------------------------------------
  • 请查看警报以获取更多详细信息,或查看消息。工程
sysadmin@dd4500# alerts show  current-detailed alert-id mo-307
 
messages.engineering
Aug 13 04:17:21 dd4500 ddfs[14768]: INFO: Event posted: mo-307 Sun Aug 13 04:17:20 2023 CRITICAL Filesysm Tier=ECS EVT-FMIG-00001: Data Movement has encountered an error. EVT-OBJ::Tier=ECS-INFO::Cause=CP space is full
  • 检查云许可证
    • 是否已达到许可容量?
       
Capacity licenses:
##   Feature              Shelf Model   Capacity     Mode        Expiration Date
--   ------------------   -----------   ----------   ---------   ---------------
1    CLOUDTIER-CAPACITY   n/a           136.42 TiB   permanent   n/a
--   ------------------   -----------   ----------   ---------   ---------------
  • 检查配置
    • 是否为 mtree 列出了正确的云单元
    • 必须在 DD 中正确设置云单元。 
    • 备份应用程序无法修改 DD 中设置的目标设备。
sysadmin@dd4500# data-movement policy show
Mtree                          Target(Tier/Unit Name)    Policy           Value      
-----------------              ----------------------                 ---------        -----------
/data/col1/mtree1   Cloud/cloudunit1               age-range   14-100 days 
-----------------              ----------------------                 ---------        -----------
  • 检查数据移动状态
sysadmin@dd4500 # data-movement status
Data-movement to cloud tier:
----------------------------
Data-movement is initializing..
Data-movement recall:
---------------------
No recall operations found.
  • 检查云清理状态
    • 云清理和数据移动不能同时运行
sysadmin@dd4500# cloud clean status
Previous cloud tier cleaning attempt was unsuccessful.
 Failure reason:
cloud unit "cloudunit2" did not have sufficient cleanable data.
Cloud tier cleaning finished at 2017/03/15 12:16:06.
  • 检查日志
Fmig = File migration
  • 搜索 ddfs.info 日志以查找数据移动条目。 
  • 在数据移动前后在日志中搜索“Fmig”,以检查文件迁移操作的顺序。
 

Produtos afetados

Data Domain
Propriedades do artigo
Número do artigo: 000216771
Tipo de artigo: How To
Último modificado: 29 mar. 2024
Versão:  1
Encontre as respostas de outros usuários da Dell para suas perguntas.
Serviços de suporte