PowerEdge: 16G - VPD access failed in RHEL kernel log for 24x2.5 NVMe Gen5 switch backplane

Resumo: Observed "VPD access failed" in Red Hat Enterprise Linux (RHEL) kernel log for (CPU Direct Attach) 24x2.5 NVMe Gen5 switch backplane.

Este artigo aplica-se a Este artigo não se aplica a Este artigo não está vinculado a nenhum produto específico. Nem todas as versões do produto estão identificadas neste artigo.

Sintomas

PowerEdge 16G platforms with 24x2.5 NVMe switch active backplane, the following error message is logged in the kernel log, as shown in Figure 1.
Linux Kernel log with VPD access failed message
Figure 1: Kernel log with "VPD access failed."

 

Causa

This issue is not related to hardware or firmware and does not affect any functional behavior of the backplane. 
Support of Vital Product Data (VPD) capability is optional, and the NVMe switch active backplane does not implement this feature.

Resolução

This is working as designed.

Produtos afetados

PowerEdge R760, PowerEdge R760XA, PowerEdge R760xd2, PowerEdge R760xs, PowerEdge R7625, Red Hat Enterprise Linux Version 9, Red Hat Enterprise Linux Version 8
Propriedades do artigo
Número do artigo: 000223372
Tipo de artigo: Solution
Último modificado: 13 jan. 2026
Versão:  3
Encontre as respostas de outros usuários da Dell para suas perguntas.