Dell Networking VEP4600报告具有某些 SSD 日期代码的只读文件系统
Resumo: Dell Networking VEP4600可能会报告带有某些 SSD 日期代码的只读文件系统。本文概述了可能出现的错误以及如何识别受影响的日期代码。
Este artigo aplica-se a
Este artigo não se aplica a
Este artigo não está vinculado a nenhum produto específico.
Nem todas as versões do produto estão identificadas neste artigo.
Sintomas
VEP4600可能会遇到文件系统的读/写故障。日志显示类似于以下内容:
Apr 9 11:07:05 versa-flexvnf kernel: [5421388.862593] ata4.00: failed command: FLUSH CACHE EXT
Apr 9 11:07:05 versa-flexvnf kernel: [5421388.881723] ata4.00: status: { DRDY }
Apr 9 11:07:05 versa-flexvnf kernel: [5421388.867741] ata4.00: cmd ea/00:00:00:00:00/00:00:00:00:00/a0 tag 21
Apr 9 11:07:05 versa-flexvnf kernel: [5421388.855371] ata4.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen
Apr 9 11:07:05 versa-flexvnf kernel: [5421388.885569] ata4: hard resetting link
Apr 9 11:07:10 versa-flexvnf kernel: [5421394.207142] ata4: link is slow to respond, please be patient (ready=0)
Apr 9 11:07:15 versa-flexvnf kernel: [5421398.915488] ata4: hard resetting link
Apr 9 11:07:15 versa-flexvnf kernel: [5421398.910945] ata4: COMRESET failed (errno=-16)
Apr 9 11:07:20 versa-flexvnf kernel: [5421404.246725] ata4: link is slow to respond, please be patient (ready=0)
Apr 9 11:07:25 versa-flexvnf kernel: [5421408.934531] ata4: COMRESET failed (errno=-16)
Apr 9 11:07:25 versa-flexvnf kernel: [5421408.939075] ata4: hard resetting link
Apr 9 11:07:30 versa-flexvnf kernel: [5421414.290309] ata4: link is slow to respond, please be patient (ready=0)
Apr 9 11:08:00 versa-flexvnf kernel: [5421444.001617] ata4: limiting SATA link speed to 3.0 Gbps
Apr 9 11:08:00 versa-flexvnf kernel: [5421443.997078] ata4: COMRESET failed (errno=-16)
Apr 9 11:08:00 versa-flexvnf kernel: [5421444.001619] ata4: hard resetting link
Apr 9 11:08:05 versa-flexvnf kernel: [5421449.029612] ata4: EH complete
Apr 9 11:08:05 versa-flexvnf kernel: [5421449.025412] ata4: reset failed, giving up
Apr 9 11:08:05 versa-flexvnf kernel: [5421449.029600] ata4.00: disabled
Apr 9 11:08:05 versa-flexvnf kernel: [5421449.020870] ata4: COMRESET failed (errno=-16)Causa
具有特定日期代码的VEP4600存在 SSD 变为只读的风险。受影响的具体日期代码是:
- 2308
- 2310
- 2312
查找日期代码
在 Versa OS 或 Dell DIAG-OS 中以根用户身份运行以下命令:”smartctl -i /dev/sda“
响应应在响应的第五行包含一个序列号字段,其值类似于:YCA12310230490181
日期代码是序列号中 YCA1 之后开始的四位数值。在下面的示例中,2310 是日期代码。
versa@versa-flexvnf:~$ sudo smartctl -i /dev/sda
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-4.4.0-151-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: 256GB SATA Flash Drive
Serial Number: YCA12310230490181
LU WWN Device Id: 6 71190a 55bd0d0d0
Firmware Version: SFDN004E
User Capacity: 256,060,514,304 bytes [256 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Apr 21 22:17:43 2021 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
此示例设备受到影响。
Resolução
如果标识的代码与上述任何日期代码匹配,请联系支持部门以开始服务更换流程。
Produtos afetados
DELL NETWORKING VEP4600 16-CORE, Dell Networking VEP4600 4-CORE, DELL NETWORKING VEP4600 8-COREPropriedades do artigo
Número do artigo: 000291005
Tipo de artigo: Solution
Último modificado: 09 abr. 2025
Versão: 2
Encontre as respostas de outros usuários da Dell para suas perguntas.
Serviços de suporte
Verifique se o dispositivo está coberto pelos serviços de suporte.