PowerStore: RSC does not function after NDU

Сводка: After upgrading PowerStore software, RSC shows as enabled but RSC credentials do not work for Remote Access via SupportAssist.

Данная статья применяется к Данная статья не применяется к Эта статья не привязана к какому-либо конкретному продукту. В этой статье указаны не все версии продуктов.

Симптомы

Even though RSC has been enabled by the customer prior to the upgrade, Support/Services are unable to use RSC credentials to gain remote access to the PowerStore.  Regular SSH password still works, and operation of the system and SupportAssist functionality is otherwise unaffected.

This issue affects all PowerStore OS versions from 2.0 through 3.2.

Причина

The reinitialize of SupportAssist that occurs as part of the final steps of the upgrade ends up removing the supporting filesystems and recreating them, but there is a missing step in reinitiating RSC support.

Разрешение

Disabling and reenabling SupportAssist will resolve the issue. It is recommended to wait 15 minutes before restarting to ensure that the SupportAssist was disabled.

If the issue persists, contact technical support for assistance.

Затронутые продукты

PowerStore, PowerStoreOS

Продукты

SupportAssist
Свойства статьи