摘要: This article explains what a predictive drive failure (error code PDR16) means, why it occurs, and provides step-by-step instructions to troubleshoot and resolve the issue. It covers recommended actions such as backing up data, updating firmware, and replacing the disk if necessary to ensure storage health and prevent data loss. ...
本文章適用於
本文章不適用於
本文無關於任何特定產品。
本文未識別所有產品版本。
說明
What is Predicted Drive Failure and how to solve it?
Predictive drive failure alerts indicate that a hard disk may fail soon based on error trends detected by SMART monitoring or the RAID controller. This is a critical warning for storage health and should be addressed immediately to prevent data loss.
Typically the alert gets triggered by:
- Self-Monitoring, Analysis, and Reporting Technology
(SMART) detecting errors
Modern drives include extra space to reallocate bad blocks. However, if errors persist, the drive may need replacement.
Sometimes, firmware or reporting issues can cause false alerts, so updating firmware is recommended before replacing any hardware.
How To Troubleshoot Predictive drive failure?
Note: If multiple drives reporting PDR16 or SMART errors are seen, then contact Dell Support.
- Always perform a backup before any steps are taken.
- Predictive failure means that the disk could fail at any time. Ensure that all critical data is backed up before proceeding.
- Export a SupportAssist collection log that includes a controller log.
- Replace the hard drive (PD) and ensure the virtual disk (VD) is optimal.
Note:
- For hard drive replacement procedure, refer to PowerEdge: How To Install or Hot Swap a Replacement Hard Drive
- For Self-Dispatch service for your parts, browse How to use Self-Dispatch service for your PowerEdge server
- Perform firmware updates to:
- Hard Drive
- iDRAC
- RAID controller
- Note: Reboot is required to complete firmware install for a RAID card.
- More information about firmware update is located in the Dell article Updating Firmware and Drivers on Dell PowerEdge Servers.
More troubleshooting or maintenance may be required to ensure the health of the array.
Note: This article is part of the Server Tutorials: "RAID and Disks" available at PowerEdge Tutorials: Physical Disk Drives and RAID Controller (PERC) on Servers
受影響的產品
C Series, Rack Servers, Tower Servers, XE Servers, XR Servers, iDRAC7, iDRAC8, iDRAC9, SupportAssist Enterprise, OEM Server Solutions, PowerFlex custom node, Poweredge FC430, Poweredge FC630, PowerEdge FC640, Poweredge FC830, PowerEdge FD332
, PowerEdge FM120x4 (for PE FX2/FX2s), PowerEdge M630, PowerEdge M630 (for PE VRTX), PowerEdge M640, PowerEdge M640 (for PE VRTX), PowerEdge M830, PowerEdge M830 (for PE VRTX), PowerEdge MX5016s, PowerEdge MX740C, PowerEdge MX750c, PowerEdge MX760c, PowerEdge MX840C, PowerFlex appliance R650, PowerFlex appliance R6525, PowerFlex appliance R660, PowerFlex appliance R6625, Powerflex appliance R750, PowerFlex appliance R760, PowerFlex appliance R7625, PowerFlex appliance R640, PowerFlex appliance R740XD, PowerFlex appliance R7525, PowerFlex appliance R840
...
產品
HS Series, Modular Infrastructure文章屬性
文章編號: 000126418
文章類型: How To
上次修改時間: 08 12月 2025
版本: 31
向其他 Dell 使用者尋求您問題的答案
支援服務
檢查您的裝置是否在支援服務的涵蓋範圍內。