Prerequisites for M1000e (with MXL), Cisco Nexus, Brocade, and Dell Compellent

The following table describes the prerequisites for the FCoE solution offered using M1000e (with MXL), Cisco Nexus, Brocade, and Dell Compellent. For more information, see http://en.community.dell.com/techcenter/extras/m/white_papers/20387203

Resource Prerequisites
MXL
  • DCB needs to be enabled.

  • VLT needs to be disabled.

  • FIP Snooping feature needs to be enabled on the MXL.

    conf
                                                          Feature fip-snooping
                                                       
  • Port-channel member interfaces needs to have following configuration.

    interface range tengigabitethernet 0/33 – 36
                                                          port-channel-protocol lacp
                                                          port-channel 128 mode active
                                                          exit
                                                          
                                                          protocol lldp
                                                          no advertise dcbx-tlv ets-reco
                                                          dcbx port-role auto-upstream
                                                          no shut
                                                          exit
                                                       
  • Port-channel connecting Cisco Nexus switch needs to have following configuration.

    interface port-channel 128
                                                          portmode hybrid
                                                          switchport
                                                          fip-snooping port-mode fcf
                                                       
  • Server facing ports needs to have following configuration.

    portmode hybrid
                                                          switchport
                                                          protocol lldp
                                                          dcbx port-role auto-downstream
                                                          no shutdown
                                                          exit
                                                       
Cisco Nexus

Following is the prerequisite for Cisco Nexus:

  • Enable “npv” feature on the switch. This requires switch reboot and old configuration will be wiped off. (Ensure to backup the configuration before enabling the feature)

    conf
                                                          feature npv
                                                       
  • Enable required features .

    feature fcoe
                                                          feature npiv
                                                          feature lacp
                                                       
  • Create new VSAN — instantiate it in the VSAN database.

    conf
                                                          vsan database
                                                          vsan <vsan id>
                                                       
  • Configure regular Ethernet VLANs, and then the FCoE VLAN is created with an assignment to its respective VSAN

    vlan <fcoe vlan>
                                                          fcoe vsan <vsan>
                                                       
  • Instantiate but do not configure the upstream port-channel (LAG) to the core /aggregation switch.

  • Instantiate but do not configure the downstream port-channel (LAG) to the IOA4.

  • Create the VFC interface to bind to the servers CNA FIP MAC address. This can be located in the CMC WWN table or the iDRAC page for the server.

    For Example

    interface vfc101
                                                          bind mac-address 5C:F9:DD:16:EF:07
                                                          no shutdown
                                                          
                                                          interface vfc102
                                                          bind mac-address 5C:F9:DD:16:EF:21
                                                          no shutdown
                                                       
  • Move back into the VSAN database and create entries for the new VFC just created and create entries for the FC ports that are used.

    vsan database

    vsan 2 interface vfc101

    vsan 2 interface vfc102

    vsan 2 interface fc2/1

    vsan 2 interface fc2/2

    • NOTE: All the Dell Compellent ports need to part of the same VSAN.
Brocade

Alias needs to be created having Dell Compellent fault domain WWPN accessible on Brocade switch.

Dell Compellent

Nothing specific for ASM.