Dell EMC PowerEdge R7415 Installation and Service Manual

Installing a cooling fan

The procedure for installing standard and high performance fans is identical.

Prerequisites

NOTE: Opening or removing the system cover when the system is on may expose you to a risk of electric shock. Exercise utmost care while removing or installing cooling fans.

Follow the safety guidelines listed in Safety instructions.

Steps

  1. Holding the release tab, place the cooling fan into the cooling fan cage.
  2. Route the cooling fan cable through the guides on the cooling fan cage.
  3. Connect the cooling fan cable to the connector on the system board.
    Figure 1. Installing a cooling fan
    This image shows installing cooling fan
    1. On the system with 8 x 3.5 inch [redundant power supply], 12 x 3.5 inch, and 24 x 2.5 inch drive, connect the fan 1 cable to the connector on the power interposer board (PIB).
      Figure 2. Connecting the fan cable to the PIB connector
      This image shows connecting fan cable to PIB connector

Next steps

  1. Installing the air shroud.
  2. Follow the procedure listed in After working inside your system.