Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell FluidFS Version 6.0 FS8600 Appliance Deployment Guide

PDF

Example of Single-Appliance FC 1GbE Cluster Configuration

The following example shows the best-practices configuration for single-appliance Fibre Channel 1GbE clusters.

  • Client network – Each FS8600 controller has multiple connections to each stacked Ethernet switch.
  • Internal network – The FS8600 controllers are directly connected to each other with four Ethernet cables.
  • Fibre Channel SAN – Each FS8600 controller has a connection to each FC fabric (Storage Center fault domain).
Figure 1. Single-Appliance Fibre Channel 1GbE Cluster Configuration With an SC9000 Storage System Configuration of a single-appliance FC 1GbE cluster with an SC9000 storage system
  1. Client network
  2. Internal network
  3. Fibre Channel SAN switch
  4. SC9000 with 1Gb FC ports
  5. Client network connections
  6. FS8600 internal network connections
  7. Storage Center fault domain 1 connections
  8. Storage Center fault domain 2 connections

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\