Description
PCIe card device name displayed on the iDRAC GUI and CMC GUI are not same for Broadcom/Qlogic 10G card.
Resolution
Refer to the iDRAC GUI, it is accurate and current.
Versions/Systems Affected
None
Description
An error occurs while importing CMC configuration file using local racadm or remote racadm.
Resolution
This issue occurs when IPv6 is enabled or disabled from the configuration file. Enable or disable IPv6 using the command, racadm config -g cfgIPv6LanNetworking -o cfgIPv6Enable 0.
Versions/Systems Affected
CMC for PowerEdge FX2 1.10 or later
Description
MCM Inventory report has limited RAID and NIC details. There is a difference in the RAID and NIC inventory details on the Server Component Update page and the MCM inventory report.
Resolution
In the CMC GUI, refer to the Server Overview -> Update -> Server Component Update page, it is accurate and current.
Versions/Systems Affected
All CMC versions including CMC 2.00 for Dell EMC PowerEdge FX2/FX2s.
Description
The value of "Power Available for Server Power-on” can increase after PSU failure and recovery, without any changes to the underlying chassis hardware components.
Resolution
For actual power consumption of the chassis, in the CMC GUI, navigate to the
page.Versions/Systems Affected
All the versions of FX2/FXs