This table lists the operating and storage specifications of your OptiPlex 5090 Tower.
Airborne contaminant level: G1 as defined by ISA-S71.04-1985
| Description | Operating | Storage |
|---|---|---|
| Temperature range |
10 °C–35°C (50 °F–95°F) |
-40°C-65°C (-40°F-149°F) |
| Relative humidity (maximum) |
20% to 80% (non-condensing, Max dew point temperature = 26°C) |
5% to 95% (non-condensing, Max dew point temperature = 33°C) |
| Vibration (maximum)* |
0.26 GRMS random at 5 Hz to 350 Hz |
1.37 GRMS random at 5 Hz to 350 Hz |
| Shock (maximum) |
Bottom half-sine pulse with a change in velocity of 50.8 cm/sec (20 in./sec) |
105G half-sine pulse with a change in velocity of 133 cm/sec (52.5 in./sec) |
| Altitude range |
3048 m (10,000 ft) |
10,668 m (35,000 ft) |
* Measured using a random vibration spectrum that simulates user environment.
† Measured using a 2 ms half-sine pulse when the hard drive is in use.