Dell OpenManage Server Administrator Version 11.0.1.x Release Notes
Known issues in Server Administrator on all supported operating systems
The table lists known issues in Server Administrator that are applicable to on all the supported operating systems.
| Issue ID | Functional area | Description | Workaround or Resolution |
|---|---|---|---|
| Not available | Error on Command Log page | The command log page in the Server Administrator UI may display an error message indicating that the XML is malformed. | You must clear the command log from the CLI using the omconfig system cmdlog action=clear command. |
| DF531509 | BIOS Setup Page Password | The setup and system password configuration from the Server Administrator UI or CLI is successful. But the password is displayed as blank instead of an asterisk (*) on the F2 BIOS page. | Not available |
| BITS040184 | iDRAC user privileges | User in iDRAC user authentication page showing operator privilege(iDRAC user privileges) is displayed as Custom in Server Administrator. | Not available |
| Not available | BIOS Setup, Server preferences, and SNMP configuration | On clicking the Apply button twice on the BIOS Setup page, the Server preference page and SNMP configuration page, the Server Administrator logs out from the current session. | Not available |
| Not available | XML parsing errors | Typing omreport system esmlog/alertlog/cmdlog -fmt tbl command on the CLI results in XML parsing errors if the size of the log is large. Use the UI or the omreport system esmlog/alertlog/cmdlog CLI command to view the contents of the log. | Not available |
| Not available | Restore the previous certificate and Invalid root certificate. | When you import an invalid root certificate into Server Administrator from . Then try to connect to the application after restarting the web server, a blank page is displayed. | To fix this issue, restore your original
keystore.db file before importing a valid root certificate. To restore the
keystore.db
file, use both the basic operating system commands and the Server Administrator Command Line Instrumentation (CLI). Perform the following steps from your operating system command line:
|
| Not available | Temperature drop below threshold | A temperature drop below a minimum failure threshold does not cause a system reset even if this alert action is set. | Not available |
| Not available | Unsecured HTTP requests | All unsecured HTTP requests to Server Administrator receive an invalid response. Server Administrator runs only one instance of the web server, which is secure. Make all connections through https://<ip address>: <port number>. Any http://<ip address>: <port number> request for connection with the server receives an invalid response. | Not available |
| Not available | Temperature in whole numbers | Temperature probe values and settings are only supported for whole degrees, not tenths of a degree. Setting a fractional value for the minimum warning temperature threshold results in the set value being rounded off to the next whole number value. This behavior may cause the minimum warning threshold to have the same value as the minimum failure threshold. | Not available |
| Not available | Session Management | If you close the browser using the
Close button on the browser or log off from the operating system, the Server Administrator session is not terminated. This session is listed in the Session Management page until the either of the following:
|
Not available |
| Not available | Operating system time zone | When you change the operating system time zone to a new time zone, Server Administrator session management does not display the new specified time zone. | Restart Server Administrator to display the accurate time for the time zone in the Session Management page. |
| 112708 | Memory critical error | Memory critical error is not cleared from OMSA even after replacing the DIMM and clearing SEL logs. When a Dual-Inline Memory Module (DIMM) generates errors, memory states of the DIMMs are not automatically cleared even after the failing DIMM is replaced. | To clear the memory errors, run the command: dcicfg64 command=clearmemfailures. The binary dcicfg is present in the OpenManage Server Administrator (OMSA) suite and runs the command from a shell command. |
| 131581 | Unresponsive OMSA when iDRAC is Reset to Default | Open Manage Server Administrator Services are unresponsive when the Integrated Remote Access Controller (iDRAC) is rebooting or when Reset to Default is in progress. | Not available |
| 148035 | vFlash support | On Server Administrator, vFlash is not supported from Dell PowerEdge 15th generation servers and later. | Not available |
| 148988 | non-ASCII characters | While logging to the Server Administrator UI, the login may fail if the password contains the non-ASCII characters. For example, the Euro symbol is €. | Not available |
| 158772 | OMSA debrand settings | On a debranded Server, if Server Administrator services are not running, the omreport command-line utility and the Server Administrator UI defaults to display the Server as a Dell Server. It occurs as the server is unable to access the debrand settings of the Server Administrator. | Not available |
| 162678, 163534 | OMSA memory event | The memory event on the Server Administrator alert log displays the corresponding alert more than once occasionally. | Not available |
| 161422 | OMSA keysigning | On generation of the certificate on the Server Administrator UI, the keysigning algorithm preference is disabled. When an attempt is made through the Server Administrator CLI to configure a different keysigning algorithm, a return code of success is displayed. But it does not reconfigure. The keysigning algorithm remains the same with which the certificate was generated. | Not available |
| 182493 | Adapter properties information | On the Server Administrator UI slots page, the adapter properties information is shown as Not Obtained. | To get these values, see either the Card documentation or iDRAC interface. |
| 186602 | Alert timestamp | When two or more alerts are intermittently generated with the same timestamp, then the listed order in the logs may not be sequential. | Not available |
| 192275 | Unable to change the IntNic1Port1BootProto BIOS option | Server Administrator is unable to change the BIOS setup option, IntNic1Port1BootProto in Dell PowerEdge 14th generation servers with legacy BIOS because of the BIOS limitations. | Use the RACADM utility to change the LegacyBootProto of the associated NIC. |
| 230627 | Connecting Server Administrator Web Server (DWS) to Red Hat Enterprise Linux 9.0 operating systems | The Server Administrator Web Server (DWS) feature is not functional to manage Red Hat Enterprise Linux 9.0 node. On any supported systems with Server Administrator installed, the Server Administrator Web Server (DWS) is unsuccessful to connect to Red Hat Enterprise Linux 9.0 operating system. The Red Hat Enterprise Linux 9.0 operating system runs with Remote Enablement installed. The following message is displayed: Login failed connection timeout. | For more information about installation procedure and resolution, see the Post installation configuration for Remote Enablement section in Dell OpenManage Installation Guide—Linux. |
| 229356 | Server Administrator | On PowerEdge 14G and earlier servers, an inconsistency is observed in memory alert logs between iDRAC and OMSA, for the following memory hardware event: The system memory has uncorrectable multi-bit memory errors in the non-execution path of memory device at the location DIMM_A1. Immediately replace the DIMM. On the iDRAC Lifecycle Log, the MessageID is correctly displayed as MEM9072. However, Server Administrator Alert Log, operating system log, or SNMP trap displays MessageID as MEM7199 and MEM6004 for the same memory event. | See iDRAC Lifecycle log for further actions. |
| 241150, 242330 | Field Replaceable Unit (FRU) Information | Devices that are connected to PCIe slots are not detected as FRU devices on the Server Administrator System Components (FRU) Information page. | Not available |
| 241564 | FRU Information | On the Server Administrator System Components (FRU) Information page, the name of a device that is connected by using SlimLine cable is displayed as SlimLine <IndexNumber>. For example, PERC controllers that are connected through SlimLine cable display the Device name as SlimLine<Index number> instead of PERC<Index number>. | Not available |
| 241930 | OpenManage Systems Management Software installer | During the initial installation of the Server Administrator and a supported Microsoft Windows operating system, the iDRAC Service Module (iSM) Knowledge Base page reference is not displayed in the Install Wizard Completed window of the Dell OpenManage Systems Management Software installer. | Retry the installation of Server Administrator. |
| 261207 | Server Administrator CLI | When you export a Public-Key Cryptography Standards (PKCS) certificate using the command:
omconfig preferences webserver attribute=exportcsr, the following warning messages are displayed in the Server Administrator CLI:
WARNING: An illegal reflective access operation has occurred WARNING: Illegal reflective access by security.X509.common.Certificates file:/C:/Program%20Files/Dell/SysMgt/apache-tomcat/webapps/omsa/WEB-INF/lib/OMSA.jar) to constructor sun.security.pkcs10.PKCS10Attribute(sun.security.pkcs.PKCS9Attribute) WARNING: Please consider reporting this to the maintainers of security.X509.common.Certificates WARNING: Use --illegal-access=warn to enable warnings of further illegal reflective access operations WARNING: All illegal access operations will be denied in a future release The CSR file is saved as C:\Program Files\Dell\SysMgt\apache-tomcat\temp\dell.csr. Command successful. |
The warning messages can be ignored. There is no functional impact to the Server Administrator. |
| 253846 | Server Administrator version and OpenJDK version | When a proxy server is configured on a host operating system, the following are not displayed in the Server Administrator
About page:
|
Not available |
| 267881, 265046 | BIOS Setup | When you reboot Dell PowerEdge 16G servers after updating the BIOS Setup page, the following error message is displayed on the BIOS Setup page: Error!NoBIOS Setup found on this system. | To resolve the error, restart Data Manager service. |