Dell OpenManage Server Administrator Version 11.0.1.x Release Notes
Resolved issues
| Issue ID | Functional area | Description |
|---|---|---|
| 254584 | Deleting SSL ciphers | On the Server Administrator Server Preferences page, when one or more ciphers are deleted from the SSL Ciphers attribute field, the Server Administrator UI is unsuccessful to launch. |
| 256358, 256659 | Blank or invalid SSL ciphers | An incorrect message is displayed in the Server Administrator UI when you do the following:
|
| 250847 | Duplicate NVMe Add-In Cards (AICs) | When one or more NVMe AICs are connected to a PowerEdge server after a cold boot, duplicate NVMe AICs are displayed in the following:
|
| 230606 | Server Administrator SELinux policy | When you install and uninstall the SELinux policy of Server Administrator, the following error message is displayed: uavc: op=load_policy lsm=selinux seqno=6 res=1. It is displayed on systems running the Red Hat Enterprise Linux 9.0 operating system with SELinux. |
| 245115 | Server Administrator BIOS setup | When you run the omreport chassis biossetup command on the Server Administrator CLI, the following error message is displayed and the Server Administrator BIOS Setup page does not respond. This error is observed when PowerEdge MX760 and C6620 servers running on Linux operating systems are idle. |
| 248236 | Physical disk in foreign state | On Physical Disks included Non-importable span page, all the physical disks which are in Foreign state are not displayed. |
| 247391 | STOR0210 alert message | When SATA HDD drives are inserted to PowerEdge 16G servers, the STOR0210 alert messages with NULL value are displayed in the Alert Log page. |
| 247748 | Inserting physical disk | On PERC 11 and earlier controllers, the following CTL48 alert message (Traditional alert 2326) is not logged after inserting the physical disks: A foreign configuration was detected on controller. |
| 246927 | Micron M.2 drives attached to BOSS-N1 controllers. | When Micron M.2 NVMe drives are attached to BOSS-N1 controllers on the Physical Devices on Controller page, the PCIe Maximum Link Speed and PCIe Negotiated Link Speed value is incorrectly displayed as 8.0 GT/s. |
| 251110 | Server Administrator Data Manager | When Failed and Ready state physical disks are used to create a virtual disk of any RAID level from CLI, the Server Administrator Data Manager is not functional. The physical disks are attached to PERC 12 controllers. |
| 295459 | Local Privilege Escalation (LPE) | On Microsoft Windows operating systems, a critical vulnerability which enabled to escalate local privileges using Command-Line Interface (CLI) is resolved. |
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\