Event ID — 2342

Description
The Check Consistency found inconsistent parity data. Data redundancy may be lost.
Severity
Warning / Non-critical
Cause and Action
Cause: The data on a source disk and the redundant data on a target disk is inconsistent.

Action: Restart the Check Consistency task. If you receive this alert again, check the health of the physical disks included in the virtual disk. Review the alert messages for significant alerts related to the physical disks. If you suspect that a physical disk has a problem, replace it and restore from backup.

Related Alert Information
Clear Alert Number: None

Related Alert Number: 2341, 2343

Local Response Agent (LRA) Number: 2080