show fc ns switch

Displays the details of the FC NS switch parameters.

Syntax
show fc ns switch [brief]
Parameters
None
Default
Not configured
Command Mode
EXEC
Usage Information
None
Example
OS10# show fc ns switch

Total number of devices = 1
Switch Name                 10:00:14:18:77:13:38:28
Domain Id                   4
Switch Port                 port-channel10(Eth 1/1/9)
FC-Id                       04:00:00
Port Name                   50:00:d3:10:00:ec:f9:05
Node Name                   50:00:d3:10:00:ec:f9:00
Class of Service            8
Symbolic Port Name          Compellent Port QLGC FC 8Gbps; Slot=06 Port=01 in Controller: SN 60665 of Storage Center: DEVTEST 60665
Symbolic Node Name          Compellent Storage Center: DEVTEST 60665
Port Type                   N_PORT
Registered with NameServer  Yes
Registered for SCN          No
Example (brief)
OS10# show fc ns switch brief
Total number of devices = 1
Intf#                       Domain   FC-ID      Enode-WWPN              Enode-WWNN
port-channel10(Eth 1/1/9)     4     04:00:00   10:00:00:90:fa:b8:22:18 20:00:00:90:fa:b8:22:18
Supported Releases
10.3.1E or later

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\