VXLAN and BGP EVPN Configuration Guide for Dell EMC SmartFabric OS10 Release 10.5.2
show nve replicators
Displays all the replicators and their states.
- Syntax
- show nve replicators [vnid vnid]
- Parameters
- None
- Default
- None
- Command mode
- EXEC
- Usage information
When you specify the VNID, the output displays details about the service nodes available for the VNID.
- Example (without VNID)
OS10# show nve replicators Codes: * - Active Replicator BFD Status:Enabled Replicators State ----------------------- 2.2.2.3 Up 2.2.2.2 Up OS10# show nve replicators
- Example (with VNID)
OS10# show nve replicators vnid 10009 Codes: * - Active Replicator BFD Status:Enabled Replicators State ----------------------- 2.2.2.3 Up 2.2.2.2* Up
*— indicates service node to which the VTEP sends BUM traffic for the specific VNID.
- Supported releases
- 10.4.3.0 or later