Dell EMC XC Core XC450 Installation and Service Manual
Drive indicator codes
The LEDs on the drive carrier indicates the state of each drive. Each drive carrier has two LEDs: an activity LED (green) and a status LED (bicolor, green/amber). The activity LED blinks whenever the drive is accessed.

- Drive activity LED indicator
- Drive status LED indicator
- Drive capacity label
NOTE:If the drive is in the Advanced Host Controller Interface (AHCI) mode, the status LED indicator does not power on.
NOTE:Drive status indicator behavior is managed by Storage Spaces Direct. Not all drive status indicators may be used.
| Drive status indicator code | Condition |
|---|---|
| Blinks green twice per second | Indicates that the drive is being identified or preparing for removal. |
| Off | Indicates that the drive is ready for removal.
NOTE:The drive status indicator remains off until all drives are initialized after the system is powered on. Drives are not ready for removal during this time.
|
| Blinks green, amber, and then powers off | Indicates that there is an expected drive failure. |
| Blinks amber four times per second | Indicates that the drive has failed. |
| Blinks green slowly | Indicates that the drive is rebuilding. |
| Solid green | Indicates that the drive is online. |
| Blinks green for three seconds, amber for three seconds, and then powers off after six seconds | Indicates that the rebuild has stopped. |