Dell PowerEdge T550 Installation and Service Manual
Removing the BOSS S2 module
Prerequisites
- Follow the safety guidelines listed in Safety instructions.
- Follow the procedure that is listed in Before working inside your system.
- Remove the air shroud.
- If installed, remove the front bezel.
- Disconnect the cables connected to the system board.
Steps
- Using a Phillips 2 screwdriver, remove the screw securing the BOSS S2 module to the system.
- Slide the BOSS S2 module out of the system.
NOTE:The procedure to remove the BOSS S2 module is similar for all configurations.
Figure 1. Removing the BOSS S2 module 
Figure 2. Removing the BOSS S2 module 
- Align the blank with the BOSS S2 module slot and push it into the bay until it clicks into place.
NOTE:Blanks must be installed in empty slots to maintain FCC certification of the system. The blanks also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system.
Figure 3. Installing the BOSS S2 module blank 