Dell PowerEdge XE9785 Installation and Service Manual
Front View of the System

| Item | Ports, panels, and slots | Icon | Description |
|---|---|---|---|
| 1 | Handle | N/A | Handle used to move the chassis. |
| 2 | OCP NIC | N/A | This port supports OCP 3.0. |
| 3 | GPU sled | N/A | GPU sled which contains supported GPUs. |
| 4 | iDRAC dedicated RJ45 ports | ![]() | Enables you to remotely access iDRAC. when the front iDRAC ports are connected with the network. |
| 5 | Handle | N/A | Handle used to move the chassis. |
| 6 | CAM handle | N/A | CAM handle enables you to slide the HPM sled out of the chassis. |
| 7 | Right control panel | N/A | Contains the system ID, power button, Type-C USB port, and the ambient sensor vent. |
| 8 | Handle | N/A | Handle used to move the chassis. |
| 9 | PCIe slots | N/A | Enables you to connect the PCI Express expansion
cards. NOTE:For PowerEdge XE9785 with MI355X
GPUs, slots 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 can be
used |
| 10 | Express Service Tag | N/A | The Express Service Tag is a slide-out label panel that contains system information such as Service Tag, NIC, MAC address, and so on. If you have opted for the secure default access to iDRAC, the Information tag will also contain the iDRAC secure default password. |
| 11 | PCIe slots | N/A | Enables you to connect the PCI Express expansion cards. |
| 12 | PCIe slots | N/A | Enables you to connect the PCI Express expansion cards. |
| 13 | Handle | N/A | Handle used to move the chassis. |
| 14 | Left control panel (LCP) | N/A | Contains the USB port and Mini-Displayport. |

NOTE:OSFP ports are available only in the NVIDIA B300 GPU
configuration. AMD MI355X GPU configuration does not support the OSFP ports.
| Item | Ports, panels, and slots | Icon | Description |
|---|---|---|---|
| 1 | Handle | N/A | Handle used to move the chassis. |
| 2 | OSFP ports | N/A | OSFP ports for communication. |
| 3 | GPU sled | N/A | GPU sled which contains supported GPUs. |
| 4 | OSFP ports | N/A | OSFP ports for communication. |
| 5 | Handle | N/A | Handle used to move the chassis. |
| 6 | iDRAC dedicated RJ45 ports | ![]() | Enables you to remotely access iDRAC. when the front iDRAC ports are connected with the network. |
| 7 | CAM handle | N/A | CAM handle enables you to slide the HPM sled out of the chassis. |
| 8 | Right control panel | N/A | Contains the system ID, power button, Type-C USB port, and the ambient sensor vent. |
| 9 | Handle | N/A | Handle used to move the chassis. |
| 10 | PCIe slots | N/A | Enables you to connect the PCI Express expansion
cards. NOTE:For the XE9785 with B300 GPUs,
slot 3, 6, 9 and 12 can be used. |
| 11 | Express Service Tag | N/A | The Express Service Tag is a slide-out label panel that contains system information such as Service Tag, NIC, MAC address, and so on. If you have opted for the secure default access to iDRAC, the Information tag will also contain the iDRAC secure default password. |
| 12 | PCIe slots | N/A | Enables you to connect the PCI Express expansion cards. |
| 13 | PCIe slots | N/A | Enables you to connect the PCI Express expansion cards. |
| 14 | Handle | N/A | Handle used to move the chassis. |
| 15 | Left control panel (LCP) | N/A | Contains the USB port and Mini-Displayport. |
| 16 | OCP NIC | N/A | This port supports OCP 3.0. |