Dell PowerEdge XR8720t Installation and Service Manual

PDF

Removing the M.2 NVMe SSD module from the Dual M.2 riser

Prerequisites

  1. Follow the safety guidelines listed in the Safety instructions.
  2. Follow the procedure listed in Before working inside your system.
  3. Remove the dual M.2 riser.

Steps

  1. Loosen and remove the screw securing the M.2 NVMe SSD.
  2. Lift the M.2 NVMe SSD module and then slowly pull the card outward to disconnect from thee connector.
    Figure 1. Removing the M.2 NVMe SSD module from the riser - Slot 0
    This image shows the removing the M.2 NVMe SSD module from the riser
    Figure 2. Removing the M.2 NVMe SSD module from the riser - Slot 1
    This image shows the removing the M.2 NVMe SSD module from the riser
    NOTE:The steps to remove the SSD from Slot 0 and Slot 1 are the same.