Configure VLT domain

The next step is to configure a VLT domain on each MX5108n switch. It contains the exact same VLT domain on each switch. In this case, create a VLT domain '101' on each switch. The backup destination for the A1 MX5108n switch is the IPv4 address of the A2 MX5108n switch. Similarly, the backup destination for the A2 MX5108n switch is the IPv4 address of the A1 MX5108n switch. Create a unique MAC address to make identifying and troubleshooting easier by running the following commands:
MX7K-IOM-A2#
                                 MX7K-IOM-A2# configure terminal
                                 MX7K-IOM-A2(config)# vlt-domain 101
                                 MX7K-IOM-A2(conf-vlt-101)# discovery-interface ethernet1/1/9,1/1/10:1
                                 MX7K-IOM-A2(conf-vlt-101)# backup destination 100.71.96.121
                                 MX7K-IOM-A2(conf-vlt-101)# vlt-mac 00:11:22:33:55:66
                                 MX7K-IOM-A2(conf-vlt-101)# exit
                                 MX7K-IOM-A2(config)# exit
                                 MX7K-IOM-A2#
                              