| 1 |
1 |
TPM detection failure |
Replace the system board. |
| 1 |
2 |
Unrecoverable SPI flash failure |
Replace the system board. |
| 1 |
3 |
Short in hinge cable tripped OCP1 |
Check if the display-assembly cable (EDP)
is seated properly or pinched at the hinges. If the problem persists,
replace the display assembly (LCD). |
| 1 |
4 |
Short in hinge cable tripped OCP2 |
Check if the display-assembly cable (EDP)
is seated properly or pinched at the hinges. If the problem persists,
replace either display-assembly cable (EDP) or display assembly (LCD).
|
| 1 |
5 |
EC unable to program i-Fuse |
Replace the system board. |
| 1 |
6 |
EC internal failure |
Disconnect all power source (AC,
battery, coin cell) and drain flea power by pressing and holding down
the power button for 3 - 5 seconds. |
| 1 |
7 |
Non-RPMC Flash on boot guard fused system |
Replace the system board. |
| 2 |
1 |
Processor failure |
Replace the system board. |
| 2 |
2 |
System board: BIOS or ROM (Read-Only
Memory) failure |
Replace the system board. |
| 2 |
3 |
System board: No memory or RAM
(Random-Access Memory) detected |
Replace the system board. |
| 2 |
4 |
System board: Memory or RAM
(Random-Access Memory) failure |
Replace the system board. |
| 2 |
5 |
System board: Memory or RAM (Random-Access Memory) failure |
Replace the system board. |
| 2 |
6 |
System-board or chipset error |
Replace the system board. |
| 2 |
7 |
Display failure - SBIOS message |
Replace the display assembly (LCD).
|
| 2 |
8 |
Display failure - EC detection of power
rail failure |
Replace the system board. |
| 3 |
2 |
PCI of video card/chip failure |
Replace the system board. |
| 3 |
3 |
BIOS recovery image not found |
Flash latest BIOS version. If the problem
persists, replace the system board. |
| 3 |
4 |
BIOS recovery image found but invalid |
Flash latest BIOS version. If the problem
persists, replace the system board. |
| 3 |
5 |
Power-rail failure |
EC ran into power sequencing failure. If
the problem persists, replace the system board. |
| 3 |
6 |
System BIOS Flash corruption. |
Flash corruption is detected by SBIOS. If
the problem persists, replace the system board. |
| 3 |
7 |
Management Engine (ME) error |
Timeout waiting on ME to reply to HECI
message. If the problem persists, replace the system board. |
| 4 |
1 |
Memory or RAM (Random-Access Memory)
failure
|
Replace the system board. |
| 4 |
2 |
Processor
failure |
Replace the system board. |