iDRAC8 with Lifecycle Controller Version 2.70.70.70 Release Notes
Important notes
- When FCP is enabled, 'Default Password Warning' setting is disabled after changing the default user password.
- Keyboard interactive authentication has been enabled on the iDRAC SSH Server to provide enhanced security. SSH clients now require both password authentication and keyboard interactive authentication before allowing a user to log in to iDRAC. If you see a message - "Further authentication required.", you have to include keyboard interactive authentication in your login attempt.
- After updating the iDRAC firmware to version 2.70.70.70 or later, LC logs may display a message—"Version change detected for PCIe SSD firmware. Previous version: X.X.X, Current version: X.X.X.". Ignore this log entry.
- Failover LOM is not supported with Intel 10 GbE 4P X710-k bNDC on a modular server.
- The drivers that are exposed by LC are present in a read-only drive that is labeled OEMDRV and the drive is active for 18 hours. During this period:
- You cannot install any DUPs.
- LC cannot invoke CSIOR.
However, if an AC power cycle (cold boot) is performed, the OEMDRV drive is automatically deleted.
- CPLD firmware update has no impact on Trusted Platform Module enablement.
- Depending on the virtual storage device attached through iDRAC, that is, USB drive or CD/DVD .ISO file, LC displays Virtual Floppy or Virtual CD respectively.
- If Test Network Connection fails for a valid address, try configuring the network settings again. If the issue persists, restart the system and retry the operation.
- When you reset or update the iDRAC, you must reboot LC if it is launched already. If you fail to reboot, LC may behave unexpectedly.
- On PowerEdge FC630, PowerEdge FC830, and PowerEdge FC430 systems, part replacement is not supported if a single PERC (FS332) is replaced with a dual PERC (FD332) or vice versa.
- After performing a firmware update or rollback operations from LC, the host is rebooted by default. Reboot the host server again to display the updated firmware versions in the View Current Versions wizard.
- To record updates in the Lifecycle log, ensure that the Lifecycle Controller and iDRAC are from the same release.
- If Lifecycle Controller and iDRAC are not from the same release, the Lifecycle Log displays either blank messages or messages with a '~' character.
- When you update a 12th generation PowerEdge server backplane-expander firmware for PowerEdge R920 firmware to version 0.33 or 2.03, the comparison page displays only one expander entry. However, firmware for both the expanders is updated.
- Fibre channel NIC cards with two or four ports are displayed as a single port card in Lifecycle Controller. However, all ports are updated when a firmware update is performed.
- The option to enable or disable the disk cache policy for SWRAID controllers is supported only on SWRAID controller driver version 4.1.0-0025 or later.
- ResetKeys under Action in the SecureBoot resource is available only on systems with supported BIOS.
- The SecureBoot navigation link is available under Computer System only if the SecureBoot feature is supported by the BIOS installed on the system.
- Rollback is not supported for CPLD.
- If SMBv2 share fails in Lifecycle GUI, ensure that:
- The Digitally sign communications option is disabled
- Permissions to access the folder/file are granted
- Folder/file name does not have a space
- Share contains fewer files and folders
- The certificate warning message that is displayed during an HTTPS transaction is due to the server presenting a certificate issued by an entity that is not trusted by the system, or certificate that is presented by the server is expired.
- Firmware update from downloads.dell.com using LCUI with HTTP and HTTPS proxy is not supported.