Dell Technologies 14th Generation PowerEdge Server Troubleshooting Guide
Troubleshooting a wet system
Steps
- Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
- Remove the system cover.
-
Remove the following components (if installed) from the system:
- Power supply unit(s)
- Optical drive
- Hard drives
- Hard drive backplane
- USB memory key
- Hard drive tray
- Cooling shroud
- Expansion card risers (if installed)
- Expansion cards
- Cooling fan assembly (if installed)
- Cooling fan(s)
- Memory modules
- Processor(s) and heat sink(s)
- Processor and heat sink module
- System board
- Mezzanine card
- Power distribution boards
- Midplanes
- Let the system dry thoroughly for at least 24 hours.
- Reinstall the components you removed in step 3 except the expansion cards.
- Install the system cover.
-
Turn on the system and attached peripherals.
If the problem persists, see the Getting help section.
- If the system starts properly, turn off the system, and reinstall all the expansion cards that you removed.
- Run the appropriate diagnostic test. For more information, see the Using system diagnostics section.
Next steps
If the tests fail, see the Getting help section.