Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products

Dell EMC PowerEdge R740xd Technical Specifications

Thermal restrictions

Following table lists the configuration required for efficient cooling.

Table 1. Thermal restrictions configurationFollowing table describes the configuration required for efficient cooling.
Configuration Number of processors Heatsink Processor/DIMM blank DIMM blanks Type of air shroud Fan
PowerEdge R740xd 1 One 1U standard heat sink for CPU ≤ 125 W Required Not required Standard Four standard fans and one blank to cover two fan slots
One 2U standard heat sink for CPU > 125 W
PowerEdge R740xd 2 Two 1U standard heat sink for CPU ≤ 125 W Not required Not required Standard Six standard fans
Two 2U standard heat sink for CPU > 125 W
PowerEdge R740xd with mid bay 1 One 1U high performance heat sink Required Required Not required Six high performance fans
PowerEdge R740xd with mid bay 2 Two 1U high performance heat sink Not required Required Not required Six high performance fans
PowerEdge R740xd with GPU 2 Two 1U high performance heat sink Not required Not required GPU air shroud Six high performance fans
PowerEdge R740xd with rear drive only 1 One 1U standard heat sink for CPU ≤ 125 W Required Not required Standard Six high performance fans
One 2U standard heat sink for CPU > 125 W
PowerEdge R740xd with rear drive only 2 Two 1U standard heat sink for CPU ≤ 125 W Required Not required Standard Six high performance fans
Two 2U standard heat sink for CPU > 125 W

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\