Dell Lifecycle Controller GUI v2.70.70.70 User's Guide
Breaking mirrored drives
To split the
mirrored array of RAID-1 virtual drives:
- Start Lifecycle Controller.
- In the left pane, click Hardware Configuration.
- In the right pane, click Configuration Wizards.
- Under Storage Configuration wizards, click Break Mirror.The Break Mirror page is displayed with the mirrored virtual drives.
- Select the related controller and click Finish.NOTE: The Break Mirror feature does not support software RAID controllers.NOTE: For more information about the break mirror feature, see the Performing a Break-Mirror Operation Using Lifecycle Controller white paper at www.delltechcenter.com/lc.The system automatically turns off even if one mirrored array is successfully delinked.