Dell DD and PowerProtect Hardware 8.0 Features and Specifications
Back panel
The back panel has two dual power supplies and two LCCs (Link Controller Cards).

Each controller has 4 SAS ports (laid out as 2 pairs). Standard systems and systems with the licensed HA feature only use ports 0 and 2 on each controller. Ports 1 and 3 typically have a plastic plug blocking the unused ports to make inserting a cable into the correct ports easier.
| Light | Quantity | Color | Meaning |
|---|---|---|---|
| Controller power | 1 per controller | Green | On when the Controller is powered on. |
| Controller fault | 1 per controller | Amber | On when either the Controller or a SAS connection is faulty. On during power-on self test. |
| Link active | 4 per controller | Blue | On when the host connection is active. |
| Power supply input voltage | 1 per power supply | Green | Input power green when it is working. |
| Power supply fault* | 1 per power supply | Amber |
|
The DS60 continues to run with a single power supply and two fans (out of the three fans).