Dell DD and PowerProtect Hardware 8.0 Features and Specifications
DD9300 and ES30 shelf guidelines
The system rediscovers newly configured shelves after it restarts. You can power off the system and recable shelves to any other position in a set, or to another set. To take advantage of this flexibility, you need to follow these rules before making any cabling changes:
- Do not exceed the maximum shelf configuration values for your system as listed in the following table below.
- Use the Installation and Setup Guide for your system to minimize the chance of a cabling mistake.
- A system cannot exceed its maximum raw external shelf capacity, regardless of added shelf capacity.
- DD6800 systems support ES30 SATA shelves after controller upgrades from older models.
- ES30 SATA shelves must be on their own chain.
| DD system | Memory required (GB) | SAS cards/ port per card | ES30 support (TB) | Max shelves per set | Max number of sets | Max external capacity available (TB) 1 | Max RAW external capacity (TB) 2 |
|---|---|---|---|---|---|---|---|
| DD9300 | 192 | 2x4 | SAS 30, 45, 60; SATA 15, 30, 45 | 7 3 | 4 | 384 | 480 |
| DD9300 w/ Expanded Capacity 4 | 384 | 2x4 | SAS 30, 45, 60; SATA 15, 30, 45 | 7 3 | 4 | 720 | 900 |
| DD9300 w/ Expanded Capacity or w/ HA 4 | 384 | 2x4 | SAS 30, 45, 60 | 7 3 | 4 | 720 | 900 |
| DD9300 w/ ER | 384 | 2x4 | SAS 30, 45, 60; SATA 15, 30, 45 | 7 3 | 4 | 1440 | 1800 |
| DD9300 Expanded Capacity w/ Cloud Tier | 384 | 2x4 | SAS 30, 45, 60; SATA 15, 30, 45 | 7 3 | 4 | 720 (max), additional 192 SAS dedicated to Cloud Tier | 900 (max), additional 240 SAS dedicated to Cloud Tier |
| DD9300 w/ Expanded Capacity or w/ HA and Cloud Tier 4 | 384 | 2x4 | SAS 30, 45, 60 | 7 3 | 4 | 720 (max), additional 192 SAS dedicated to Cloud Tier | 900 (max), additional 240 SAS dedicated to Cloud Tier |
1. This figure only counts drives that have user data in the shelves.
2. The raw capacity of an ES30 is 125% of the available capacity.
3. Recommended configurations start at four shelves per set and expand beyond that as required. For HA configurations, the counts as a shelf.
4. DDOS 6.x and greater and SSD shelf configuration