NOTE:All ratings assume a fully configured DS60 shelves.
Table 1. Hardware specifications
Specification Description
AC line voltage 200 to 240 Vac ± 10%, single-phase, 47 to 63 Hz
AC line current (operating maximum) 4.9 A max at 200 Vac
Power consumption (operating maximum) 980 VA (931W) max
Power factor 0.95 min at full load, low voltage
Heat dissipation (operating maximum) 3.36 x 106 J/hr, (3177 Btu/hr) max
Dimensions (rack mounted)
  • Height: 8.75 in (22.23 cm) 5U (4U plus 1U cable management tray).
  • Width including rails: 17.50 in (44.45 cm)
  • Depth (chassis only): 34.5 in (87.63 cm)
  • Maximum depth (fully configured): 36.4 in (92.46 cm)
Shelf weight
  • Without FRUs installed: 55.0 lb ( 24.7 kg)
  • With FRUs installed: 225.0 lb (102 kg)
Operating temperature
  • Ambient temperature: 41o F to 104o F (5o C to 40o C)
  • Temperature gradient: 18o F/hr (10o C/hr)
  • Relative humidity extremes: 20% to 80% noncondensing
Recommended operating relative humidity 40% to 55% noncondensing
Operating elevation -50 to 7500 ft (-16 to 2300 m)
Non-operating (shipping and storage) temperature
  • Ambient temperature: -40o F to 149o F (-40o C to 65o F)
  • Temperature gradient: 45o F/hr (25oC/hr)
  • Relative humidity: 10% to 90% noncondensing
  • Elevation: -50 to 35,000 ft (-16 to 10,600 m)