Dell DD and PowerProtect Hardware 8.0 Features and Specifications

PDF

Rear LED indicators

The rear elements containing LEDs include each power supply, each I/O module, and the management module.

The figure shows the rear LEDS.

Figure 1. Rear LEDs
Rear LEDs
  • 1. Management module service LEDs
  • 2. Power supply LEDs
  • 3. NVRAM LEDs
  • 4. I/O Module LEDs

The power supply LEDs include:

  • AC LED on top
  • DC LED in the middle
  • Service Required LED on the bottom
Figure 2. Power supply LEDs
Power supply LEDs
Table 1. Rear LED status indicators
Part Description or Location State
Power supply AC LED Steady green indicates normal AC input power.
Power supply DC LED Steady green indicates normal DC output power.
Power supply Service LED Solid amber indicates a failed power supply.
I/O module I/O module handle Solid green means I/O module functioning normally. Amber indicates a fault condition. Each I/O module also has per port LEDs. These LEDs are blue on the FC, and SAS I/O modules. They light when the port is active.
Management module Bicolor LED Solid green means management module functioning normally. Amber indicates that the management module requires service.