Verify the status by checking the LEDs. Controller B is located above Controller A in the center of the rear panel. The power supply/cooling units are above and below the controllers.

Facing the back panel of the FS15, the Expander ports are the outer of the two ports; the Host ports are the inner of the two ports. The ports are identified by symbols on the rear panel: a circle symbol indicates a Host port; a diamond symbol indicates an Expander port.

Figure 1. Rear panel overview
Rear panel overview
Table 1. Status LEDs
Light Quantity Color Meaning
Controller power 1 per controller Green On when the controller is powered on
Controller failure 1 per controller Amber On when either the controller or a SAS connection has failed. On during a power-on self test.
Host link active 1 per controller Blue On when the host connection is active
Expansion link active 1 per controller Blue On when the expansion host is active