PUT method for local access configuration

This method enables or disables the local access configuration in the chassis.

Description
Enables or disables the local access configuration.
Privilege
DEVICE_CONFIGURATION
HTTP response code
200

Enabling Chassis Direct feature

Example request body
{
    "SettingType": "LocalAccessConfiguration",
    "EnableChassisPowerButton": true,
    "EnableKvmAccess": true,
    "LedPresence": "Absent",
    "QuickSync": {
        "QuickSyncHardware": "Present",
        "QuickSyncAccess": "READ_WRITE",
        "EnableInactivityTimeout": true,
        "TimeoutLimit": 120,
        "TimeoutLimitUnit": "SECONDS",
        "EnableReadAuthentication": true,
        "EnableQuickSyncWifi": true
    },
    "EnableChassisDirect": true,
    "LcdAccess": "VIEW_AND_MODIFY",
    "LcdPresence": "Present",
    "LcdCustomString": "",
    "LcdLanguage": "en"
}
Example response body
{
    "SettingType": "LocalAccessConfiguration",
    "EnableChassisPowerButton": true,
    "EnableKvmAccess": true,
    "LedPresence": "Absent",
    "QuickSync": {
        "QuickSyncHardware": "Present",
        "QuickSyncAccess": "READ_WRITE",
        "EnableInactivityTimeout": true,
        "TimeoutLimit": 120,
        "TimeoutLimitUnit": "SECONDS",
        "EnableReadAuthentication": true,
        "EnableQuickSyncWifi": true
    },
    "EnableChassisDirect": true,
    "LcdAccess": "VIEW_AND_MODIFY",
    "LcdPresence": "Present",
    "LcdCustomString": "",
    "LcdLanguage": "en"
}

Disabling Chassis Direct feature

Example request body
{
    "SettingType": "LocalAccessConfiguration",
    "EnableChassisPowerButton": true,
    "EnableKvmAccess": true,
    "LedPresence": "Absent",
    "QuickSync": {
        "QuickSyncHardware": "Present",
        "QuickSyncAccess": "READ_WRITE",
        "EnableInactivityTimeout": true,
        "TimeoutLimit": 120,
        "TimeoutLimitUnit": "SECONDS",
        "EnableReadAuthentication": true,
        "EnableQuickSyncWifi": true
    },
    "EnableChassisDirect": false,
    "LcdAccess": "VIEW_AND_MODIFY",
    "LcdPresence": "Present",
    "LcdCustomString": "",
    "LcdLanguage": "en"
}
Example response body
{
    "SettingType": "LocalAccessConfiguration",
    "EnableChassisPowerButton": true,
    "EnableKvmAccess": true,
    "LedPresence": "Absent",
    "QuickSync": {
        "QuickSyncHardware": "Present",
        "QuickSyncAccess": "READ_WRITE",
        "EnableInactivityTimeout": true,
        "TimeoutLimit": 120,
        "TimeoutLimitUnit": "SECONDS",
        "EnableReadAuthentication": true,
        "EnableQuickSyncWifi": true
    },
    "EnableChassisDirect": false,
    "LcdAccess": "VIEW_AND_MODIFY",
    "LcdPresence": "Present",
    "LcdCustomString": "",
    "LcdLanguage": "en"
}
Enabling LCD Override pin
Example Response body
{    
    "SettingType": "LocalAccessConfiguration",
    "EnableChassisPowerButton": false,
	"EnableLcdOverridePin":true,
    "LcdOverridePin": 275923,
    "EnableKvmAccess": true,
    "LedPresence": "Absent",
    "QuickSync": {
        "QuickSyncHardware": "Absent",
        "QuickSyncAccess": "READ_WRITE",
        "EnableInactivityTimeout": true,
        "TimeoutLimit": 120,
        "TimeoutLimitUnit": "SECONDS",
        "EnableReadAuthentication": true,
        "EnableQuickSyncWifi": true
    },
    "EnableChassisDirect": true,
    "LcdAccess": "VIEW_AND_MODIFY",
    "LcdPresence": "Present",
    "LcdCustomString": "",
    "LcdLanguage": "en",
    }