Omconfig Set All Temperature Probe Thresholds

Table 1. Omconfig Set All Temperature Probe Thresholds . The following table describes the process to set the minimum and maximum warning temperature thresholds for all temperature probes in the enclosure.

Description

Sets the minimum and maximum warning temperature thresholds for all temperature probes in the enclosure.

  • NOTE: This command is not supported on SCSI RAID controllers.

Syntax

omconfig storage enclosure action=setalltempprobes controller=id enclosure=< ENCLOSUREID> minwarn=n maxwarn=n , where id is the controller ID. The <ENCLOSUREID> variable specifies the enclosure.

In this syntax, n is a user-specified alphanumeric string.

Example to

Set the thresholds for all temperature probes residing in enclosure 3 attached to connector 2 on controller 1, to 10 and 40 degree Celsius.

Example for SAS controllers

omconfig storage enclosure action=setalltempprobes controller=1 enclosure=2:3 minwarn=10 maxwarn=40