Dell EMC OpenManage Command Line Interface Guide Version 9.1

PDF

Omconfig System Thrmshutdown Or Omconfig Servermodule Thrmshutdown

Use the omconfig system thrmshutdown or omconfig servermodule thrmshutdown command to configure a thermal shutdown action. You can configure the system for a thermal shutdown when a temperature probe detects a temperature probe warning or failure event.

The following table displays the valid parameters for the command:

Table 1. Valid Parameters Of Thermal Shutdown . the following table describes the valid parameters such as disabled or warning or failure for the severity command.
name=value pair Description
severity=disabled | warning | failure

disabled: Disable thermal shutdown. An administrator must intervene.

warning: Perform a shutdown when a temperature warning event is detected. A warning event occurs when any temperature probe inside a chassis reads a temperature (in degree Celsius) that exceeds the maximum temperature warning threshold value.

failure: Perform a shutdown when a temperature failure event is detected. A failure event occurs when any temperature probe inside a chassis reads a temperature (in degree Celsius) that exceeds the maximum temperature failure threshold value.


Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\