Specify A Value For Minimum And Maximum Warning Thresholds

To specify values for the voltage probe warning thresholds, you must specify the number of the probe you are configuring and the minimum and/or maximum warning threshold values.

In the following example, the probe being configured is probe 0:
omconfig chassis volts index=0 minwarnthresh=1.900 maxwarnthresh=2.250
or
omconfig mainsystem volts index=0 minwarnthresh=1.900 maxwarnthresh=2.250
When you issue the command and the system sets the values you specify, the following message is displayed:
Voltage probe warning threshold(s) set successfully.