Dell EMC OpenManage Command Line Interface Guide Version 9.1

PDF

Syntax For Setting Alert Actions

Setting an alert action requires two name=value pairs. The first name=value pair is the event type. The second name=value pair is the action to take for this event. For example, in the command:
omconfig system alertaction event=powersupply broadcast=true
or
omconfig servermodule alertaction event=powersupply broadcast=true

The event is a power supply failure and the action is to broadcast a message to all Server Administrator users.