CTL1

Message
Controller event log: arg1
Arguments
arg1 = message
Detailed Description
This event is retrieved from the controller when iDRAC storage monitoring was not running. Such events which are generated in the past are logged as informational severity.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL10

Message
arg1 alarm has been tested.
Arguments
arg1 = Controller name
Detailed Description
The controller alarm test has run successfully. This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2156
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL100

Message
The Patrol Read operation was stopped and did not complete for arg1 .
Arguments
arg1 = controller name
Detailed Description
The Patrol Read operation running on the controller was stopped by user request or an issue was detected by the controller.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

CTL101

Message
The arg1 is disabled.
Arguments
arg1 = controller name
Detailed Description
The controller identified in the message is disabled by a user action.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC     ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL102

Message
The arg1 is enabled.
Arguments
arg1 = controller name
Detailed Description
The controller identified in the message is enabled by a user action.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC     ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL11

Message
Configuration on arg1 was reset.
Arguments
arg1 = controller name
Detailed Description
A user operation to reset the controller configuration was performed.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2157
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL12

Message
An invalid SAS configuration has been detected on arg1 . Details: arg2
Arguments
arg1 = Controller name, arg2 = error message
Detailed Description
The controller and attached enclosures are not cabled correctly.
Recommended Response Action
Refer to the storage hardware documentation for information on correct cabling configurations.
Category
Storage (CTL = Storage Contr)
Severity
Severity 1 (Critical)
Trap/EventID
4329
OMSA Event ID
2182
OMSA Trap ID
75400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL13

Message
The arg1 cache has been discarded.
Arguments
arg1 = Controller name
Detailed Description
The controller has flushed the cache and all data in the cache has been lost. This may occur when the system has memory or battery problems that cause the controller to distrust the cache. Although user data may have been lost, this alert does not always indicate that relevant or user data has been lost.
Recommended Response Action
Verify that the battery and memory are functioning properly.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
OMSA Event ID
2186
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL14

Message
Single-bit ECC error limit exceeded on the arg1 DIMM.
Arguments
arg1 = controller name
Detailed Description
The storage controller memory identified in th emessage is not operating correctly.
Recommended Response Action
COntact your service provider.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
OMSA Event ID
2187
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL16

Message
None of the arg1 properties are set.
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
Re-issue the command.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2218
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL17

Message
arg1 arg2 is changed to arg3 .
Arguments
arg1 = Controller Name, arg2 = propertyname, arg3 = new value
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL18

Message
Load Balance and Auto Copyback on Predictive Failure has changed for arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
Re-issue the command.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2222
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL19

Message
Abort CC on Error, Copyback, and Load Balance has changed for arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
Re-issue the command.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2223
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL2

Message
arg1 rebuild rate has changed.
Arguments
arg1 = Controller name
Detailed Description
You have changed the controller rebuild rate. This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2142
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL20

Message
Copyback and Load Balance has changed for arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
Re-issue the command.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2224
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL200

Message
The current firmware version arg1 is older than the required version arg2 for arg3 .
Arguments
arg1 = version number, arg2 = version number, arg3 = controller name
Detailed Description
The firmware on the controller identified in the message is not a supported version.
Recommended Response Action
Download the supported version from the service provider and install it on the controller.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
OMSA Event ID
2131
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

CTL201

Message
The current driver version arg1 ( arg2 ) is older than the required driver version arg3 ( arg4 ) for arg5 .
Arguments
arg1 = major verion number, arg2 = minor version number, arg3 = major version number, arg4 = minor version number, arg5 = controller name
Detailed Description
The controller driver for the identified controller is not a supported version.
Recommended Response Action
Download the supported version of the driver from the service provider and install it on the operating system.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
OMSA Event ID
2132
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

CTL202

Message
Unable to open the firmware and driver configuration file arg1 of arg2 .
Arguments
arg1 = file name, arg2 = controller name
Detailed Description
Storage Management is unable to determine whether the system has the minimum required versions of the RAID controller firmware and driver due to one of the following: 1) Incorrect installation directory path to the configuration file. 2) Removed or renamed configuration file.
Recommended Response Action
Reinstall Server Administrator Storage Management software on the operating system.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
OMSA Event ID
2165
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

CTL203

Message
Abort Check Consistency on Error, Copyback or Auto Copyback on Predictive Failure, and Load Balance values are changed for arg1 .
Arguments
arg1 = controller name
Detailed Description
The status of the changed attribute values are reported for information purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
OMSA Event ID
2219
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

CTL204

Message
Copyback or Auto Copyback on Predictive Failure and Load Balance values are changed for arg1 .
Arguments
arg1 = controller name
Detailed Description
The status of the changed attribute values are reported for information purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
OMSA Event ID
2220
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

CTL205

Message
Auto Copyback on Predictive Failure, Abort Check Consistency on Error, and Load Balance values are changed for arg1 .
Arguments
arg1 = controller name
Detailed Description
The status of the changed attribute values are reported for information purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
OMSA Event ID
2221
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

CTL206

Message
Abort Check Consistency on Error and Auto Copyback on Predictive Failure values are changed for arg1 .
Arguments
arg1 = controller name
Detailed Description
The status of the changed attribute values are reported for information purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
OMSA Event ID
2227
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

CTL207

Message
Unable to import the Virtual Disk because the supported limit is exceeded on arg1 .
Arguments
arg1 = controller name
Detailed Description
The number of Virtual Disks selected for import has exceeded the supported limit of Virtual Disks on the controller identified in the message.
Recommended Response Action
Make sure that the number of Virtual Disks selected for import is within the supported limit on the controller, and retry the operation
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
OMSA Event ID
2372
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

CTL208

Message
Unable to authenticate the entered passphrase for the arg1 .
Arguments
arg1 = controller name
Detailed Description
Unable to authenticate the entered passphrase.
Recommended Response Action
Enter the correct passphrase and retry.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
OMSA Event ID
2392
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

CTL209

Message
Enabled persistent hot spare on arg1 .
Arguments
arg1 = controller name
Detailed Description
The persistent hot spare feature is enabled on the controller identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
OMSA Event ID
2394
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

CTL21

Message
Abort CC on Error and Load Balance has changed for arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
Re-issue the command.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2225
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL210

Message
Disabled persistent hot spare on arg1 .
Arguments
arg1 = controller name
Detailed Description
The persistent hot spare feature is disabled on the controller identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
OMSA Event ID
2395
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

CTL211

Message
The arg1 property changed on arg2 through Manage Physical Disk Power option.
Arguments
arg1 = property name, arg2 = controller name
Detailed Description
The physical disk properties displayed under "Manage Physical Disk Power" option has changed.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
OMSA Event ID
2398
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

CTL212

Message
The existing encryption key in the arg1 is deleted.
Arguments
arg1 = controller name
Detailed Description
This alert is generated when the encryption key in the controller is deleted.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
OMSA Event ID
2388
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

CTL213

Message
The Local Key Management (LKM) is enabled on arg1 .
Arguments
arg1 = controller name
Detailed Description
The Local Key Management (LKM) security mode is enabled on the controller identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
OMSA Event ID
2407
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

CTL214

Message
The Local Key Management (LKM) encryption key in the arg1 has changed.
Arguments
arg1 = controller name
Detailed Description
The Local Key Management (LKM) encryption key in the controller identified in the message has changed.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
OMSA Event ID
2411
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

CTL215

Message
Redundant path disconnected on arg1 .
Arguments
arg1 = Controller Name
Detailed Description
The controller identified in the message has two connectors that are connected to the same enclosure. The communication path on one connector has lost connection with the enclosure. The communication path on the other connector is reporting this loss.
Recommended Response Action
Make sure both the cables are securely attached to the enclosure and controller. FOr more information about connecting the cables to the enclosure, see the Cables Attached Correctly section in the PERC Users Guide. Also, make sure both Enclosure Management Modules (EMMs) are healthy.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
OMSA Event ID
2250
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

CTL216

Message
Redundant path connection is restored on arg1 .
Arguments
arg1 = Controller Name
Detailed Description
The communication in the redundant path on the connectors of the controller identified in the message is restored.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
OMSA Event ID
2253
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

CTL217

Message
Redundant path view is cleared on arg1 .
Arguments
arg1 = controller name
Detailed Description
The redundant path view on the controller identified in the message is cleared.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
OMSA Event ID
2370
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

CTL22

Message
Load Balance has changed for arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
Re-issue the command.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2226
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL23

Message
Copyback and Auto Copyback on Predictive Failure has changed for arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
Re-issue the command.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2228
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL24

Message
Abort CC on Error and Auto Copyback on Predictive Failure has changed for arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
Re-issue the command.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2229
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL25

Message
Auto Copyback on Predictive Failure has changed for arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
Re-issue the command.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2230
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL26

Message
Copyback and Abort CC on Error has changed for arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
Re-issue the command.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2231
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL27

Message
The arg1 alarm is silenced.
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2232
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL28

Message
The Background Initialization (BGI) rate has changed for arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2233
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL29

Message
The Patrol Read rate has changed for arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2234
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL3

Message
arg1 alarm is enabled.
Arguments
arg1 = Controller name
Detailed Description
You have enabled the controller alarm. This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2143
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL30

Message
The Check Consistency rate has changed for arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2235
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL31

Message
Copyback is modified for arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
Re-issue the command.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2236
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL32

Message
Abort CC on Error is modified for arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
Re-issue the command.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2237
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL33

Message
The arg1 debug log file has been exported.
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2238
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL34

Message
A foreign configuration was cleared on arg1 .
Arguments
arg1 = controller name
Detailed Description
This is the result of a user operation.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2239
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL35

Message
A foreign configuration was imported on arg1 .
Arguments
arg1 = controller name
Detailed Description
The operation to import foreign configuration (virtual disks, host spares, and so on) completed successfully.
Recommended Response Action
Verify the foreign configuration was successfully imported by viewing the virtual disks and hot spares. See the hardware documentation for more information.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2240
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL36

Message
The Patrol Read mode has changed for arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2241
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL37

Message
A Patrol Read operation started for arg1 .
Arguments
arg1 = controller name
Detailed Description
A patrol read operation was initiated by the controller or the user.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2242
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL38

Message
The Patrol Read operation completed for arg1 .
Arguments
arg1 = controller name
Detailed Description
The patrol read task ended.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2243
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL39

Message
The arg1 reconstruct rate has changed.
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2267
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL4

Message
arg1 alarm is disabled.
Arguments
arg1 = Controller name
Detailed Description
You have disabled the controller alarm. This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2144
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL40

Message
Multi-bit ECC error on arg1 DIMM.
Arguments
arg1 = Controller name
Detailed Description
An error involving multiple bits has been encountered during a read or write operation. The error correction algorithm recalculates parity data during read and write operations. If an error involves only a single bit, it may be possible for the error correction algorithm to correct the error and maintain parity data. An error involving multiple bits, however, generally indicates data loss. In some cases, if the multi-bit error occurs during a read operation, then the data on the disk may be ok. If the multi-bit error occurs during a write operation, then data loss has occurred.
Recommended Response Action
Replace the Dual In-line Memory Module (DIMM). The DIMM is a part of the controller battery pack. Refer to the storage hardware documentation for information on replacing the DIMM. You may need to restore data from backup.
Category
Storage (CTL = Storage Contr)
Severity
Severity 1 (Critical)
Trap/EventID
4329
OMSA Event ID
2289
OMSA Trap ID
75400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL41

Message
Single-bit ECC error on arg1 .
Arguments
arg1 = Controller name
Detailed Description
An error involving a single bit has been encountered during a read or write operation. The error correction algorithm has corrected this error.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
OMSA Event ID
2290
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL42

Message
Enclosure Management Module (EMM) hot plug is not supported on arg1 .
Arguments
arg1 = Controller name
Detailed Description
An attempt to hot plug an Enclosure Management Module (EMM) has been detected.
Recommended Response Action
If the new enclosure and its device are not detected by the operating system, try restarting your system to verify the newly attached enclosure and its sub-components are detected. See the hardware documentation for more information.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2304
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL43

Message
Diagnostic message arg1 from arg2
Arguments
arg1 = args, arg2 = Controller name
Detailed Description
This alert is provided for informational purposes. The text for this alert is generated by the utility that ran the diagnostics and can vary depending on the situation.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2315
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL44

Message
Diagnostic message arg1 from arg2
Arguments
arg1 = message, arg2 = Controller name
Detailed Description
A diagnostics test failed. The text for this message is generated by the tool that ran the diagnostics and can vary depending on the situation.
Recommended Response Action
Refer to the storage hardware documentation for more information on the diagnostic test.
Category
Storage (CTL = Storage Contr)
Severity
Severity 1 (Critical)
Trap/EventID
4329
OMSA Event ID
2316
OMSA Trap ID
75400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL45

Message
Single-bit ECC error on arg1 .
Arguments
arg1 = Controller name
Detailed Description
The Dual In-line Memory Module (DIMM) is beginning to malfunction.
Recommended Response Action
Replace the Dual In-line Memory Module (DIMM) to avoid data loss or data corruption. The DIMM is a part of the controller battery pack. Refer to hardware documentation for information on replacing the DIMM.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
OMSA Event ID
2319
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL46

Message
Single-bit ECC error. The arg1 DIMM is critically degraded.
Arguments
arg1 = Controller name
Detailed Description
The Dual In-line Memory Module (DIMM) is malfunctioning. Data loss or data corruption may occur..
Recommended Response Action
Replace the DIMM immediately to avoid data loss or data corruption. The DIMM is a part of the controller battery pack. Refer to the storage hardware documentation for information on replacing the DIMM.
Category
Storage (CTL = Storage Contr)
Severity
Severity 1 (Critical)
Trap/EventID
4329
OMSA Event ID
2320
OMSA Trap ID
75400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL47

Message
Single-bit ECC error on arg1 .
Arguments
arg1 = Controller name
Detailed Description
The Dual In-line Memory Module (DIMM) is malfunctioning. Data loss or data corruption may occur. The DIMM must be replaced immediately.
Recommended Response Action
Replace the DIMM immediately. The DIMM is a part of the controller battery pack. Refer to your hardware documentation for information on replacing the DIMM.
Category
Storage (CTL = Storage Contr)
Severity
Severity 1 (Critical)
Trap/EventID
4329
OMSA Event ID
2321
OMSA Trap ID
75400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL48

Message
A foreign configuration was detected on arg1 .
Arguments
arg1 = controller name
Detailed Description
The controller has physical disks that were moved from another controller or have been removed and replaced on the current configuration. These physical disks contain virtual disks that were created on the current or other controller. See the storage hardware documentation for Import Foreign Configuration and Clear Foreign Configuration for more information. Foreign configuration is seen when a controller is replaced.
Recommended Response Action
Import or clear the detected foreign configuration using a configuration tool or utility.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2326
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL49

Message
The NVRAM has corrupted data on arg1 .
Arguments
arg1 = Controller name
Detailed Description
The NVRAM has corrupted data. This may occur after a power surge, a battery failure, or for other reasons. The controller is reinitializing the NVRAM.
Recommended Response Action
No response action is required as the controller is taking the required corrective action. However, If this message is generated often (such as during each reboot), then replace the controller.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
OMSA Event ID
2327
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL5

Message
Bad block replacement error on arg1 .
Arguments
arg1 = Controller name
Detailed Description
A portion of a physical disk is damaged. See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information.
Recommended Response Action
See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
OMSA Event ID
2146
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL50

Message
The arg1 NVRAM has corrupt data.
Arguments
arg1 = Controller name
Detailed Description
The NVRAM has corrupt data. The controller is unable to correct the situation.
Recommended Response Action
Replace the controller.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
OMSA Event ID
2328
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL51

Message
arg1 SAS port report: arg2
Arguments
arg1 = Controller name, arg2 = message
Detailed Description
The text for this message is generated by the controller during runtime and can vary depending on the situation.
Recommended Response Action
Make sure the SAS cables attached to the enclosure/backplane are attached securely. Refer to the storage hardware documentation for more information on checking the cables. Contact technical support if the issue persists.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
OMSA Event ID
2329
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL52

Message
arg1 SAS port report: arg2
Arguments
arg1 = Controller name, arg2 = args
Detailed Description
This alert is provided for informational purposes. The text for this alert is generated by the controller and can vary depending on the situation.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2330
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL53

Message
A controller hot plug has been detected.
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2332
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL54

Message
arg1 event log: arg2
Arguments
arg1 = Controller name, arg2 = args
Detailed Description
This alert is provided for informational purposes. The text for this alert is generated by the controller and can vary depending on the situation.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2266;2334
OMSA Trap ID
75100;80100;85100;90100;95100;100100;105100;110100;115100;120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL55

Message
arg1 event log: arg2
Arguments
arg1 = Controller name, arg2 = args
Detailed Description
The text for this alert is generated by the controller and can vary depending on the situation. This text is from events in the controller event log that were generated while Storage Management was not running.
Recommended Response Action
If there is a problem, review the controller event log and the Server Administrator alert log for significant events or alerts that may assist in diagnosing the problem. Verify the health of the storage components. See the hardware documentation for more information.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
OMSA Event ID
2335
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL56

Message
arg1 event log: arg2
Arguments
arg1 = Controller name, arg2 = args
Detailed Description
The text for this alert is generated by the controller and can vary depending on the situation. This text is from events in the controller event log that were generated while Storage Management was not running.
Recommended Response Action
See the hardware documentation for more information.
Category
Storage (CTL = Storage Contr)
Severity
Severity 1 (Critical)
Trap/EventID
4329
OMSA Event ID
2336
OMSA Trap ID
75400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL57

Message
The factory default settings were restored on arg1 .
Arguments
arg1 = controller Name
Detailed Description
The controller was reset to factory default configuration settings.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2339
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL58

Message
arg1 SAS SMP communications error arg2
Arguments
arg1 = Controller name, arg2 = args
Detailed Description
The text for this alert is generated by the firmware and can vary depending on the situation. The reference to SMP in this text refers to SAS Management Protocol.
Recommended Response Action
There may be a SAS topology error. See the hardware documentation for information on correct SAS topology configurations. There may be problems with the cables such as a loose connection or an invalid cabling configuration. See the Cables Attached Correctly section for more information on checking the cables. See the hardware documentation for information on correct cabling configurations. Verify that the firmware version is supported.
Category
Storage (CTL = Storage Contr)
Severity
Severity 1 (Critical)
Trap/EventID
4329
OMSA Event ID
2356
OMSA Trap ID
75400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL59

Message
arg1 SAS expander error: arg2
Arguments
arg1 = Controller name, arg2 = args
Detailed Description
There may be a problem with the enclosure. Verify the health of the enclosure and its components. To verify the health of the enclosure, select the enclosure object in the tree view. The Health sub-tab displays a red X or yellow exclamation point for enclosure components that are failed or degraded. See the enclosure documentation for more information.
Recommended Response Action
There may be a problem with the enclosure. Verify the health of the enclosure and its components. To verify the health of the enclosure, select the enclosure object in the tree view. The Health sub-tab displays a red X or yellow exclamation mark for enclosure components that are failed or degraded. See the enclosure documentation for more information.
Category
Storage (CTL = Storage Contr)
Severity
Severity 1 (Critical)
Trap/EventID
4329
OMSA Event ID
2357
OMSA Trap ID
75400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL6

Message
Bad block sense error from arg1
Arguments
arg1 = Controller name
Detailed Description
A portion of a physical disk is damaged. See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information.
Recommended Response Action
See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
OMSA Event ID
2147
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL60

Message
A user has discarded data from the arg1 cache.
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2360
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL61

Message
Physical disks found missing from configuration during boot time on arg1 .
Arguments
arg1 = Controller name
Detailed Description
The controller has detected a change in the storage configuration between since its last shut down. This can generally happen if some configured physical disks are removed from the system when the system was shutdown.
Recommended Response Action
Shut down the system. Re-insert the removed physical disks and re-start the system.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
OMSA Event ID
2361
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL62

Message
arg1 on arg2 has missing drives and will go offline at boot.
Arguments
arg1 = VD names, arg2 = Controller name
Detailed Description
Physical disk(s) have been removed from a virtual disk. The virtual disk will be in Failed state during the next system reboot. This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2362
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL63

Message
Previous configuration was found completely missing during boot time on arg1 .
Arguments
arg1 = Controller name
Detailed Description
The controller is unable to retrieve storage configuration saved during last shut down. This can generally happen if some configured physical disks are removed from the system when the system was shutdown.
Recommended Response Action
Shut down the system. Re-insert the removed physical disks and re-start the system.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
OMSA Event ID
2364
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL64

Message
Attempted to import Unsupported Virtual Disk type RAID arg1 on arg2 .
Arguments
arg1 = args, arg2 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2371
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL65

Message
Attempted to import Unsupported Virtual Disk type RAID arg1 on arg2 .
Arguments
arg1 = args, arg2 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL66

Message
Attempted to import Unsupported Virtual Disk type RAID arg1 on arg2 .
Arguments
arg1 = args, arg2 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2373
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL67

Message
Attempted to import Virtual Disk with missing span on arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2374
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL68

Message
Attempted to import Virtual Disk with missing Physical Disk on arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2375
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL69

Message
Attempted to import virtual disk with outdated physical disk information on arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2376
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL7

Message
Bad block medium error on arg1 .
Arguments
arg1 = Controller name
Detailed Description
A portion of a physical disk is damaged. See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information.
Recommended Response Action
See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
OMSA Event ID
2148
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL70

Message
Attempted to import an orphan drive on arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2377
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL71

Message
Attempted to import an incompatible Physical Disk on arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2378
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL72

Message
The foreign configuration overflow has occurred on arg1 .
Arguments
arg1 = Controller name
Detailed Description
There is too much foreign configuration data to be imported in one attempt.
Recommended Response Action
Import these foreign configurations in multiple attempts.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
OMSA Event ID
2379
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL73

Message
Foreign configuration is imported only partially. Some configurations failed to import on arg1 .
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2380
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL74

Message
Preserved cache detected on arg1 .
Arguments
arg1 = controller name
Detailed Description
The controller has preserved data in the cache from a virtual disk, which it can no longer locate. No data loss has occurred as the controller is saving these operations in its cache.
Recommended Response Action
Check for the existence of a foreign configuration and import if any. Check that enclosures are cabled correctly.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
OMSA Event ID
2258
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL75

Message
Preserved cache discarded on arg1 .
Arguments
arg1 = controller name
Detailed Description
The controller cache was discarded by the user. Data may have been lost or corrupted.
Recommended Response Action
If data was corrupted or lost, restore the data to the disk from a backup copy.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
OMSA Event ID
2257
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL76

Message
A configuration command could not be committed to disk on arg1
Arguments
arg1 = Controller name
Detailed Description
The controller encountered errors while applying the configuration on the physical disks. The configuration command applied has not taken effect.
Recommended Response Action
Re-issue the failed configuration command or try with a different set of physical disks. Contact technical support if the problem persists.
Category
Storage (CTL = Storage Contr)
Severity
Severity 1 (Critical)
Trap/EventID
4329
OMSA Event ID
2401
OMSA Trap ID
75400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL77

Message
Flash of new firmware image(s) completed on arg1
Arguments
arg1 = Controller Name
Detailed Description
This alert message occurs if controller firmware is flashed successfully.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

CTL78

Message
Firmware image arg1 is flashing on arg2 .
Arguments
arg1 = args, arg2 = Controller Name
Detailed Description
This alert message occurs if controller firmware is flashed.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL79

Message
Controller in arg1 is not supported and will not be powered on.
Arguments
arg1 = controller slot
Detailed Description
This controller does not support features required for this chassis. This controller will not be powered on to prevent data loss.
Recommended Response Action
Replace the controller with a supported controller.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC        

CTL8

Message
Bad block extended sense error on arg1 .
Arguments
arg1 = Controller name
Detailed Description
A portion of a physical disk is damaged. See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information.
Recommended Response Action
See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
OMSA Event ID
2149
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL80

Message
arg1 experienced the following warning during startup: arg2 .
Arguments
arg1 = controller name, arg2 = controller message
Detailed Description
The controller identified in the message has an issue as displayed in the message.
Recommended Response Action
To resolve this issue, see Troubleshooting section in the Dell Shared PowerEdge RAID Controller (SPERC8) documentation.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC        

CTL81

Message
Security key assigned to arg1 is modified.
Arguments
arg1 = controller name
Detailed Description
The security key assigned to the controller identified in the message is modified.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

CTL82

Message
arg1 is functioning normally.
Arguments
arg1 = controller name
Detailed Description
The controller identified in the message is functioning normally.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

CTL83

Message
Communication with arg1 has been lost.
Arguments
arg1 = controller name
Detailed Description
The management controller is not communicating with the storage controller identified in the message. This may be because of any one of the following: a) PCIe subsystem is has stopped functioning b) An issue in the storage controller c) An issue in the management controller.
Recommended Response Action
Restart the server. If the issue persists, contact your service provider.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔* ✔*        

CTL84

Message
arg1 is running an unsupported firmware version.
Arguments
arg1 = controller name
Detailed Description
The firmware on the controller identified in the message is not supported by this version of the CMC. This may result in degraded functionality.
Recommended Response Action
Update the CMC Firmware to the latest version available or revert the controller firmware to a previous version.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL85

Message
arg1 is operating at less than optimal bandwidth.
Arguments
arg1 = controller name
Detailed Description
The controller identified in the message experienced a PCIe training error and is operating at less than full bandwith. Until this issue is resolved, a reduction in the storage performace is expected.
Recommended Response Action
Perform a Powercycle operation on the Chassis. If the issue persists, contact your service provider.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL86

Message
arg1 is operating in Fault Tolerant Mode.
Arguments
arg1 = controller name
Detailed Description
The controller is operating in conjuction with another controller to service the same set of virtual and physical disks, providing better redundancy.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL87

Message
arg1 settings do not match the settings of its peer.
Arguments
arg1 = controller name
Detailed Description
One or more settings on the controller identfed in the message do not match the settings of its peer controller. This can cause issues in a fault tolerant setup.
Recommended Response Action
Make sure that each controller is using the same setting by reconfiguring the settings of the identified controller.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔* ✔*        

CTL88

Message
arg1 firmware does not match the firmware of its peer controller.
Arguments
arg1 = controller name
Detailed Description
The firmware running on the controller identified in the message does not match the firmware version of its peer controller. This can cause issues in a fault tolerant setup.
Recommended Response Action
Make sure each controller is using the same firmware by updating the firmware of the identified controller.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL89

Message
arg1 is no longer fault tolerant because the peer controller is not available.
Arguments
arg1 = controller name
Detailed Description
The peer controller is no longer active in this fault tolerant pair. This can be a temporary situation.
Recommended Response Action
Check the chassis log for issues with the peer controller. If the peer controller does not resume normal operations after 5 minutes contact your service provider.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL9

Message
Bad block extended medium error on arg1 .
Arguments
arg1 = Controller name
Detailed Description
A portion of a physical disk is damaged. See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information.
Recommended Response Action
See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
OMSA Event ID
2150
OMSA Trap ID
75300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL90

Message
arg1 is not operating in Fault Tolerant Mode because of an incomptible peer controller.
Arguments
arg1 = controller name
Detailed Description
The peer controller is not compatible with the contoller identified in the message because of a hardware mismatch.
Recommended Response Action
Replace the peer controller with the same model controller as the controller identified in the message.
Category
Storage (CTL = Storage Contr)
Severity
Severity 1 (Critical)
Trap/EventID
4329
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL91

Message
arg1 is unable to communicate with its peer.
Arguments
arg1 = controller name
Detailed Description
The controller identified in the message is unable to communicate with its peer. This can be because of a cabling issue.
Recommended Response Action
Check the cabling between the PERC cards and the expanders. If this does not resolve the issue then contact your service provider.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL92

Message
arg1 is not operating in Fault Tolerant Mode because of an incompatible license setting on its peer controller.
Arguments
arg1 = controller name
Detailed Description
The controller identified in the message licensed features do not match its peer.
Recommended Response Action
Update the license on the peer controller.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL93

Message
arg1 has been successfully changed to operate in Fault Tolerant mode.
Arguments
arg1 = controller name
Detailed Description
The controller identified in the message has been changed to operate as part of a fault tolerant pair.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL94

Message
arg1 has been successfully changed to operate in single controller mode.
Arguments
arg1 = controller name
Detailed Description
The controller identified in the message has been changed to operate as a single controller and not as part of a fault tolerant pair.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL95

Message
arg1 has left the fault tolerant pair.
Arguments
arg1 = controller name
Detailed Description
The controller identified in the message has stopped operating in a fault tolerant mode.
Recommended Response Action
This situation may resolve itself in a few minutes. If the situation does not resolve itself or this message is repeated, contact your service provider.
Category
Storage (CTL = Storage Contr)
Severity
Severity 2 (Warning)
Trap/EventID
4330
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

CTL96

Message
arg1 has entered safe mode with limited functionality due to arg2
Arguments
arg1 = controller name, arg2 = controller message
Detailed Description
The controller identified in the message has an issue as displayed in the message.
Recommended Response Action
To resolve this issue, see Troubleshooting section in the Dell Shared PowerEdge RAID Controller (SPERC8) documentation.
Category
Storage (CTL = Storage Contr)
Severity
Severity 1 (Critical)
Trap/EventID
4329
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC        

CTL97

Message
arg1 personality changed to arg2 mode.
Arguments
arg1 = controller name, arg2 = new mode
Detailed Description
The controller identified in the message has been changed to a new personality mode (HBA or RAID).
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
OMSA Event ID
2446
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

CTL98

Message
Security key assigned to arg1 .
Arguments
arg1 = controller name
Detailed Description
The security key provided as input has been assigned to the controller identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

CTL99

Message
Security key assigned to arg1 is deleted.
Arguments
arg1 = controller name
Detailed Description
The security key assigned to the controller identified in the message is deleted.
Recommended Response Action
No response action is required.
Category
Storage (CTL = Storage Contr)
Severity
Severity 3 (Informational)
Trap/EventID
4331
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\