Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Event and Error Message Reference Guide for 13th Generation Dell PowerEdge ServersVersion 1.2

PDF

DH Event Messages

DH001

Message
Resource needed to perform the operation is unavailable.
Detailed Description
Resource temporarily unavailable
Recommended Response Action
Try again. If the error persists, use RACADM command racreset to clear the issue.
Category
Configuration (DH = Cert Mgmt)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

DH002

Message
Internal I/O failure
Detailed Description
Internal I/O failure
Recommended Response Action
Try again. If the error persists, use RACADM command racreset to clear the issue.
Category
Configuration (DH = Cert Mgmt)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

DH003

Message
Service tag could not be read
Detailed Description
Service Tag Missing
Recommended Response Action
Try again. If the error persists, use RACADM command racreset to clear the issue.
Category
Configuration (DH = Cert Mgmt)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

DH004

Message
iDRAC does not have sufficient free resources to generate keys
Detailed Description
Error generation Keys
Recommended Response Action
Boot the OS. If the error persists, contact technical support.
Category
Configuration (DH = Cert Mgmt)
Severity
Severity 1 (Critical)
No alerts are applicable for this message

DH005

Message
CA Cert is corrupted, expired, or does not have signing privileges.
Detailed Description
Invalid CA Cert
Recommended Response Action
Close other iDRAC sessions and activities. Try again.
Category
Configuration (DH = Cert Mgmt)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

DH006

Message
Not the right passphrase for the private key (need to re-write).
Detailed Description
Invalid Passphrase
Recommended Response Action
Validate that the certificate parameter matches the certificate contents; the certificate can be validated using OpenSSL tools.
Category
Configuration (DH = Cert Mgmt)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

DH007

Message
The password unlocked the private key but it was the wrong private key.
Detailed Description
CA priv key/CA Cert mismatch
Recommended Response Action
Check that the private key parameter is correct. The passphrase can be validated against the private key, passphrase, and certificate can be validated using OpenSSL tools.
Category
Configuration (DH = Cert Mgmt)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

DH008

Message
There was a problem saving the certificate to persistent storage.
Detailed Description
Unable to save the provided client certificate to internal persistent storage.
Recommended Response Action
Try again. If the error persists, use RACADM command racresetcfg to clear the issue.
Category
Configuration (DH = Cert Mgmt)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

DH009

Message
The operation did not complete successfully because of an unexpected internal problem..
Detailed Description
An unexpected internal problem has occurred and the operation did not complete successfully.
Recommended Response Action
Remove AC power from the system and re-apply AC power to the system. After the server restarts, retry the operation. If the issue persists, contact your service provider.
Category
Configuration (DH = Cert Mgmt)
Severity
Severity 1 (Critical)
No alerts are applicable for this message

DH010

Message
Reset iDRAC to apply new certificate. Until iDRAC is reset, the old certificate will be active.
Detailed Description
The iDRAC must be reset to apply a new certificate. Until the iDRAC has reset, the old certificate will be active.
Recommended Response Action
Reset the iDRAC. The iDRAC can be reset by pressing the Identify button for 15 seconds. Using the RACADM command line utility, run "racadm racreset"
Category
Configuration (DH = Cert Mgmt)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\