Troubleshooting
PowerProtect Data Manager software updates
Review the following information related to updating the
PowerProtect Data Manager software.
Installing an update package immediately fails with a
500 error
A package update might fail immediately after attempting to install it and display the following error:
500: Failed to start the update process.
The service is unavailable.
The
Sysmgr.log file shows entries similar to the following:
[c.e.b.s.s.UpgradeServiceImpl.upgradeAppliance(474)] - Failed to add certificate to KeyStore /data01/brs/upload/dellemc-ppdm-upgrade-sw-19.13.0-20.pkg (1).dellemc-ppdm-upgrade-sw-19.13.0-20.pkg (1).pkg (No such file or directory)
java.io.FileNotFoundException: /data01/brs/upload/dellemc-ppdm-upgrade-sw-19.13.0-20.pkg (1).dellemc-ppdm-upgrade-sw-19.13.0-20.pkg (1).pkg (No such file or directory)
In this example, the package name has been renamed from
dellemc-ppdm-upgrade-sw-19.13.0-20.pkg.
To resolve the issue, delete the package, upload it again, and retry the installation.
If you cannot delete the package from the user interface, perform the following procedure:
Log in to the
PowerProtect Data Manager server console using administrator credentials and change to the root user.
Run the command
cd /data01/brs/upload.
Run the command
rm <update_package>, replacing
<update_package> with the renamed update package.
Mounting a read-only file system results in a failed update
If you mount a read-only file system under the
/home/admin or
/home/sysadmin directories on the
PowerProtect Data Manager node, the update cannot complete successfully. Ensure that you remove read-only file system mounts before updating
PowerProtect Data Manager.
Automatic vCenter server discovery fails immediately after an update
An automatic vCenter server discovery might run shortly after an update, when the system is still in maintenance mode. If this discovery occurs, it fails without an error.
To determine the status of the vCenter server discovery, go to the
Infrastructure > Asset Sources window. If the discovery fails, it is restarted every 30 minutes until the vCenter server is successfully added as an asset source. You can also manually discover the vCenter server when the system is no longer in maintenance mode.