OS10 Enterprise Edition User Guide Release 10.4.0E(R3)

PDF

Collector configuration

Configure the IPv4 or IPv6 address for the sFlow collector. You can configure a maximum of two sFlow collectors. If you specify two collectors, the samples are sent to both. The agent IP address must be the same for both the collectors.

  • Enter an IPv4 or IPv6 address for the sFlow collector, IPv4 or IPv6 address for the agent, UDP collector port number (default 6343), maximum datagram size (up to 1400), and the VRF instance number in CONFIGURATION mode.
    sflow collector {
                                        ip-address | 
                                        ipv6-address} agent-addr {
                                        ip-address | 
                                        ipv6-address} [
                                        collector-port-number] 
                                        [max-datagram-size 
                                           datagram-size-number] 
                                        [vrf default]
                                     

The no form of the command disables sFlow collectors in CONFIGURATION mode.

sFlow collector
OS10(config)# sflow collector 10.1.1.1 agent-addr 2.2.2.2 6443 
                                 max-datagram-size 1500 vrf default
                              