OS10 Enterprise Edition User Guide Release 10.4.0E(R3)

PDF

lldp holdtime-multiplier

Configures the multiplier value for the hold time (in seconds).

Syntax
lldp holdtime-multiplier integer
Parameters
integer — Enter the holdtime-multiplier value in seconds (2 to 10).
Default
4 seconds
Command Mode
CONFIGURATION
Usage Information
Hold time is the amount of time (in seconds) that a receiving system waits to hold the information before discarding it. Formula: Hold Time = (Updated Frequency Interval) X (Hold Time Multiplier). The no version of this command resets the value to the default.
Example
OS10(config)# lldp holdtime-multiplier 2