Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell Command Line Reference Guide for the S4048–ON System 9.14.2.4

PDF

ipv6 route bfd

Enable BFD for all IPv6 neighbors configured through static routes.

Syntax
ipv6 route bfd [vrf vrf-name] [prefix-list prefix-list-name] [interval interval min_rx min_rx multiplier value role {active | passive}]

To disable BFD for all IPv6 neighbors configured through static routes, use the no ipv6 route bfd [vrf vrf-name] [prefix-list prefix-list-name] [interval interval min_rx min_rx multiplier value role {active | passive}] command.

Parameters
vrf vrf-name
(Optional) Enter the keyword vrf and then the name of the VRF to enable or disable BFD on the next-hop IPv6 neighbor corresponding to that VRF.
prefix-list prefix-list-name
(Optional) Enter the keyword prefix-list followed by the name of the prefix list to enable or disable BFD on specific IPv6 neighbors.
interval milliseconds
(OPTIONAL) Enter the keywords interval to specify non-default BFD session parameters beginning with the transmission interval. The range is from 50 to 1000. The default is 200.
min_rx milliseconds
Enter the keywords min_rx to specify the minimum rate at which the local system receives control packets from the remote system. The range is from 50 to 1000. The default is 200.
multiplier value
Enter the keywords multiplier to specify the number of packets that must be missed in order to declare a session down. The range is from 3 to 50. The default is 3.
role [active | passive]
Enter the role that the local system assumes:
  • Active — active system initiates the BFD session. Both systems can be active for the same session.
  • Passive — passive system does not initiate a session. It only responds to a request for session initialization from the active system.

The default is Active.

Defaults
See Parameters.
Command Modes
CONFIGURATION
Command History

This guide is platform-specific. For command information about other platforms, see the relevant Dell EMC Networking OS Command Line Reference Guide.

Version
Description
9.13(0.0)
Introduced on the S3100 series, S3048–ON, S4048–ON, S4048T-ON, S5000, S6000, S6000–ON, S6100–ON, C9010, and the Z9500.
9.12(1.0)
Introduced on the S5048F–ON.
9.11(2.5)
Introduced the ipv6 route bfd command on the Z9100–ON.
Example
DellEMC(conf)#ipv6 route bfd
DellEMC(conf)#ipv6 route bfd vrf vrf1 prefix-list p6_le

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\