Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell Command Line Reference Guide for the S4048–ON System 9.14.2.4

PDF

redundancy disable-auto-reboot

Prevent the S-Series stack management unit, stack member unit, and standby unit from rebooting if they fail.

Syntax
redundancy disable-auto-reboot stack-unit [1–6 | members]

To return to the default, use the no redundancy disable-auto-reboot stack-unit command.

Parameters
stack-unit
Enter the stack-unit number. The range is from 1 to 6.
members
Enter the keyword members for all stack-units.
Defaults
Disabled (the failed switch is automatically rebooted).
Command Modes
CONFIGURATION
Command History

This guide is platform-specific. For command information about other platforms, see the relevant Dell EMC Networking OS Command Line Reference Guide.

Version
Description
9.10(0.0)
Introduced on the S6100–ON.
9.8(0.0P5)
Introduced on the S4048-ON.
9.8(0.0P2)
Introduced on the S3048-ON.
9.7(0.0)
Introduced on the S6000.
8.3.19.0
Introduced on the S4820T.
8.3.7.0
Introduced on the S4810.
8.3.11.1
Introduced on the Z9000.
8.3.1.0
Added the members option.
Usage Information
Enabling this command keeps the failed switch in the Failed state. The switch does not reboot until it is manually rebooted. When enabled, it is not displayed in the running-config. When disabled, it is displayed in the running-config.
Related Commands
show redundancy — displays the current redundancy status.

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\