Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell Command Line Reference Guide for the S4048–ON System 9.14.2.4

PDF

rmon alarm

Set an alarm on any MIB object.

Syntax
rmon alarm number variable interval {delta | absolute} rising-threshold value event-number falling-threshold value event-number [owner string]

To disable the alarm, use the no rmon alarm number command.

Parameters
number
Enter the alarm integer number from 1 to 65535. The value must be unique in the RMON alarm table.
variable
Enter the MIB object to monitor. The variable must be in the SNMP OID format; for example, 1.3.6.1.2.1.1.3. The object type must be a 32-bit integer.
interval
Time, in seconds, the alarm monitors the MIB variables; this is the alarmSampleType in the RMON alarm table. The range is from 5 to 3600 seconds.
delta
Enter the keyword delta to test the change between MIB variables. This is the alarmSampleType in the RMON alarm table.
absolute
Enter the keyword absolute to test each MIB variable directly. This is the alarmSampleType in the RMON alarm table.
rising-threshold value event-number
Enter the keywords rising-threshold then the value (32 bit) the rising-threshold alarm is either triggered or reset. Then enter the event-number to trigger when the rising threshold exceeds its limit. This value is the same as the alarmRisingEventIndex or alarmTable of the RMON MIB. If there is no corresponding rising-threshold event, the value is zero.
falling-threshold value event-number

Enter the keywords falling-threshold then the value (32 bit) the falling-threshold alarm is either triggered or reset. Then enter the event-number to trigger when the falling threshold exceeds its limit. This value is the same as the alarmFallingEventIndex or the alarmTable of the RMON MIB. If there is no corresponding falling-threshold event, the value is zero.

owner string
(OPTIONAL) Enter the keyword owner then the owner name to specify an owner for the alarm. This is the alarmOwner object in the alarmTable of the RMON MIB.
Defaults
owner
Command Modes
CONFIGURATION
Command History

This guide is platform-specific. For command information about other platforms, see the relevant Dell EMC Networking OS Command Line Reference Guide.

Version
Description
9.10(0.1)
Introduced on the S6010-ON and S4048T-ON.
9.10(0.0)
Introduced on the S3148.
9.10(0.0)
Introduced on the S6100-ON.
9.8(2.0)
Introduced on the S3100 series.
9.8(1.0)
Introduced on the Z9100-ON.
9.8(0.0P5)
Introduced on the S4048-ON.
9.8(0.0P2)
Introduced on the S3048-ON.
9.7(0.0)
Introduced on the S6000-ON.
9.2(1.0)
Introduced on the Z9500.
9.0.2.0
Introduced on the S6000.
8.3.19.0
Introduced on the S4820T.
8.3.11.1
Introduced on the Z9000.
8.3.7.0
Introduced on the S4810.
7.6.1.0
Introduced on the S-Series.
7.5.1.0
Introduced on the C-Series.
6.1.1.0
Introduced on the E-Series.

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\