show ip pim neighbor

View PIM neighbors.

S4048–ON

Syntax
show ip pim [vrf vrf-name] neighbor
Parameters
vrf vrf-name
(OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF.
NOTE Applies to specific VRF if input is provided, else applies to Default VRF.
Command Modes
  • EXEC
  • EXEC Privilege
Command History

This guide is platform-specific. For command information about other platforms, see the relevant Dell EMC Networking OS Command Line Reference Guide.

Version
Description
9.10(0.1)
Introduced on the S6010-ON and S4048T-ON.
9.10(0.0)
Introduced on the S3148.
9.10(0.0)
Introduced on the S6100-ON.
9.8(2.0)
Introduced on the S3100 series.
9.8(1.0)
Introduced on the Z9100-ON.
9.8(0.0P5)
Introduced on the S4048-ON.
9.8(0.0P2)
Introduced on the S3048-ON.
9.7(0.0)
Added support for VRF. Introduced on the S6000-ON.
9.5(0.1)
Introduced on the Z9500.
9.0.2.0
Introduced on the S6000.
8.3.19.0
Introduced on the S4820T.
8.3.12.0
Introduced on the S4810.
8.3.11.1
Introduced on the Z9000.
8.1.1.0
Introduced on the E-Series.
7.8.1.0
Introduced on the S-Series.
Usage Information
The following describes the show ip pim neighbor command shown in the following example.
Field
Description
Neighbor address
Displays the IP address of the PIM neighbor.
Interface
List the interface type, with either slot/port information or ID (VLAN or Port Channel), on which the PIM neighbor was found.
Uptime/expires
Displays the amount of time the neighbor has been up then the amount of time until the neighbor is removed from the multicast routing table (that is, until the neighbor hold time expires).
Ver
Displays the PIM version number.
  • v2 = PIM version 2
DR prio/Mode
Displays the Designated Router priority and the mode.
  • 1 = default Designated Router priority (use the ip pim dr-priority command)
  • DR = Designated Router
  • S = Sparse mode
Example
DellEMC# show ip pim neighbor
Neighbor   Interface  Uptime/Expires    Ver   DR
Address                                       Prio/Mode
127.87.3.4 Te 1/16    09:44:58/00:01:24  v2   1 / S
DellEMC#

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\